Your browser doesn't support javascript.
loading
Avaliação da exposição dos médicos à radiação em procedimentos hemodinâmicos intervencionistas / Evaluation of radiation exposure to physicians during hemodynamic interventional procedures
Silva, Leonardo Peres da; Maurício, Claudia Lúcia de Pinho; Canevaro, Lucía Viviana; Oliveira, Paulo Sérgio.
  • Silva, Leonardo Peres da; Universidade Federal do Rio de Janeiro. Faculdade de Medicina. Departamento de Radiologia. Rio de Janeiro. BR
  • Maurício, Claudia Lúcia de Pinho; Comissão Nacional de Energia Nuclear. Instituto de Radioproteção e Dosimetria. Serviço de Monitoração Individual Externa. Rio de Janeiro. BR
  • Canevaro, Lucía Viviana; Comissão Nacional de Energia Nuclear. Instituto de Radioproteção e Dosimetria. Departamento de Física Médica. Rio de Janeiro. BR
  • Oliveira, Paulo Sérgio; Instituto Nacional de Cardiologia Laranjeiras. Serviço de Hemodinâmica. Rio de Janeiro. BR
Radiol. bras ; 41(5): 319-323, set.-out. 2008. ilus, graf
Article in English, Portuguese | LILACS | ID: lil-496936
RESUMO

OBJETIVO:

Este trabalho avalia a distribuição de dose recebida por médicos envolvidos em procedimentos hemodinâmicos de angioplastia coronária e coronariografia. A influência de alguns fatores, como o modo de fluoroscopia pulsado ou contínuo e o local de acesso à veia e/ou artéria, foi investigada.

MATERIAIS E MÉTODOS:

Para esta avaliação foram feitas medições utilizando dosímetros termoluminescentes de LiFMg,Ti, posicionados em sete diferentes pontos do corpo dos profissionais mãos, joelho, pescoço, testa e tórax, por dentro e por fora do avental de chumbo. A dose foi avaliada, por exame, nos médicos que executaram os procedimentos (30 de angioplastia e 60 de coronariografia). Os dosímetros termoluminescentes foram calibrados na grandeza operacional equivalente de dose pessoal, Hp(d), nas profundidades de 0,07, 3 e 10 mm.

RESULTADOS:

Os resultados mostram a importância do uso do protetor de tireóide e avental de chumbo para a redução da dose recebida pelos médicos. As doses dos profissionais que executaram procedimentos por via braquial usando modo contínuo de fluoroscopia foram mais altas do que os que executaram por via femoral e modo pulsado de fluoroscopia.

CONCLUSÃO:

Este estudo mostra a necessidade de medidas adicionais de proteção e a implementação de mecanismos de treinamento em proteção radiológica para os médicos que trabalham com cardiologia intervencionista.
ABSTRACT

OBJECTIVE:

The present study evaluates the dose distribution received by physicians involved in hemodynamic procedures of coronary angiography and coronariography. The influence of some factors such as pulsed or continuous fluoroscopy mode and vein and/or artery access site was investigated. MATERIALS AND

METHODS:

Measurements have been performed with LiFMg,Ti thermoluminescent dosimeters placed on seven different sites of the practitioners' bodies hands, left knee, neck, forehead and chest, under and over the lead apron. Radiation doses for each procedure were evaluated in physicians who had performed 60 coronariography and 30 angioplasty procedures. The thermoluminescent dosimeters were calibrated in the operational quantity personal dose equivalent, Hp(d), at depths of 0.07, 3 and 10 mm.

RESULTS:

The results of the present study demonstrate the significant role played by thyroid protectors and lead aprons for reducing radiation doses received by practitioners. Occupational doses in continuous mode fluoroscopy through brachial access were higher than with pulsed mode fluoroscopy through femoral access.

CONCLUSION:

The present study has demonstrated the necessity of implementing additional protective measures as well as a mechanism of training in radiation protection for physicians involved in interventional cardiological procedures.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Physicians / Radiation Protection / Radiology, Interventional Limits: Humans Language: English / Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Comissão Nacional de Energia Nuclear/BR / Instituto Nacional de Cardiologia Laranjeiras/BR / Universidade Federal do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Physicians / Radiation Protection / Radiology, Interventional Limits: Humans Language: English / Portuguese Journal: Radiol. bras Journal subject: Diagnostic Imaging / Radiology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Comissão Nacional de Energia Nuclear/BR / Instituto Nacional de Cardiologia Laranjeiras/BR / Universidade Federal do Rio de Janeiro/BR