Trasplante heterotópico de corazón en ratas: desarrollo de un modelo de microcirugía / Heterotopic heart transplantation in rats
Olivares R., Gabriel; Parra D., Claudio; Troncoso C., Pablo.
  • Olivares R., Gabriel; Pontificia Universidad Católica de Chile. Centro de Investigaciones Médicas. Departamento de Urología. Santiago. CL
  • Parra D., Claudio; Pontificia Universidad Católica de Chile. Centro de Investigaciones Médicas. Departamento de Urología. Santiago. CL
  • Troncoso C., Pablo; Pontificia Universidad Católica de Chile. Centro de Investigaciones Médicas. Departamento de Urología. Santiago. CL
Rev. chil. cir ; 60(3): 194-197, jun. 2008. ilus
Article in Spanish | LILACS | ID: lil-504107
RESUMEN
Introducción. El trasplante de corazón heterotópico en ratas es usado en investigación experimental, particularmente en el estudio de la inmunosupresión. El objetivo del trabajo fue desarrollar un modelo de trasplante heterotópico de corazón en ratas. Material y Método. Se utilizaron ratas macho Lewis (Receptor) y Brown Norway (Donante) de 200 a 350 gr. Para el procuramiento, se realizó una incisión en mariposa del tórax y se instaló un clip metálico a la vena cava superior e inferior para infundir solución fisiológica con heparina, logrando detener los latidos cardíacos, y se seccionó la arteria pulmonar y la aorta. Las venas cavas y las pulmonares son ligadas en conjunto y seccionadas. En la rata receptora se identificó la aorta y vena cava abdominal y se instaló un clamp vascular atraumático tipo bulldog. Se realizó una anastomosis término lateral entre la aorta ascendente del donante y la aorta abdominal del receptor, y entre la arteria pulmonar del donante y la cava del receptor, con microsutura 10-0 continua. Se consideró un trasplante exitoso cuando el injerto estaba funcional por más de 24 horas, por palpación de latidos en el abdomen. Resultados. Se trasplantaron 80 ratas en total. La principal causa de pérdida del injerto fue el prolongado tiempo operatorio y la hemorragia postoperatoria. Se realizaron modificaciones en la técnica Ligadura única de las venas cavas y de las venas pulmonares, venotomía elíptica y lateral, ligadura de un vaso paralelo a la aorta que evita una hemorragia letal y reposición de volumen postoperatorio. Discusión. Es un modelo reproducible. Modificaciones de la técnica permiten disminuir el tiempo de isquemia, permitiendo un aumento en la sobrevida del injerto.
ABSTRACT

Introduction:

Heterotopic heart transplantation in rats is an experimental research model, specially used to study immunosuppression.

Aim:

To develop a model of heterotopic heart transplantation in rats. Material and

methods:

Lewis rats (as receptors) and Brown Norway rats (as donors), weighing 200 to 350 g, were used. For procurement, a butterfly chest incisión was done, a metallic clip was placed in inferior and superior vena cava to infuse a physiologic solution with heparin, stopping cardiac beats and sectioning pulmonary and aortic arteries. Pulmonary and cava veins were ligated jointly and sectioned. In the receptor rats, aorta and abdominal vena cava were identified and an atraumatic bulldog vascular clamp was placed. Termino lateral anastomoses between donor ascending aorta and receptor abdominal aorta, and between donor pulmonary artery and receptor vena cava were performed with continuous microsuture. Transplantation was considered successful when the graft was functional for more than 24 hours, determined palpating beats in the abdomen.

Results:

Eighty rats were transplanted. We main causes of graft loss were a prolonged operative time and postoperative hemorrhage. The technique was modified, using a unique ligation of cavas and pulmonary veins, elliptic and lateral venotomy, ligation of a vessel that is parallel to aorta that avoids lethal hemorrhages and postoperative fluid replacement.

Discussion:

This is a reproducible model. The technical modifications introduced, reduce the lapse of ischemia and increase graft survival.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Transplantation, Heterotopic / Heart Transplantation Type of study: Prognostic study Limits: Animals Language: Spanish Journal: Rev. chil. cir Journal subject: General Surgery Year: 2008 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Transplantation, Heterotopic / Heart Transplantation Type of study: Prognostic study Limits: Animals Language: Spanish Journal: Rev. chil. cir Journal subject: General Surgery Year: 2008 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL