Diagnóstico do ceratocone baseado no Orbscan com o auxílio de uma rede neural / Detection of keratoconus based on a neural network with Orbscan
Souza, Murilo Barreto; Medeiros, Fabrício Witzel de; Souza, Danilo Barreto; Alves, Milton Ruiz.
  • Souza, Murilo Barreto; Faculdade de Tecnologia e Ciências. Salvador. BR
  • Medeiros, Fabrício Witzel de; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Souza, Danilo Barreto; s.af
  • Alves, Milton Ruiz; USP. Faculdade de Medicina. Hospital das Clínicas. Setor de Córnea e Doenças Externas. São Paulo. BR
Arq. bras. oftalmol ; 71(6,supl.0): 65-68, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-507478
RESUMO

OBJETIVO:

Desenvolver uma rede neural artificial para classificar em normal ou portador de ceratocone os pacientes submetidos ao exame do Orbscan II TM.

MÉTODOS:

Foi realizado um estudo retrospectivo envolvendo 98 exames de 59 pacientes. Utilizando o programa Java Neural Network 1.1 foi criada uma rede neural artificial para classificar os exames entre os dois grupos (normais e portadores de ceratocone). Foram utilizados 73 exames para treinamento e validação da rede, e 25 para testar o seu funcionamento.

RESULTADOS:

Dos 73 exames utilizados no treinamento da rede, 59 eram normais e 14 mostravam alterações relacionadas ao ceratocone. O método utilizado para treinamento da rede foi o "backpropagation". A taxa de aprendizado utilizada foi de 0,2, e a taxa de tolerância de erro 0,05. Dos 25 exames utilizados para a avaliação da eficácia da rede, 19 eram normais, e 6 apresentavam ceratocone. Após o treinamento a rede apresentou sensibilidade e especificidade de 83 e 100 por cento, respectivamente.

CONCLUSÃO:

A rede neural artificial representa uma opção útil e viável para auxiliar na classificação de exames realizados com o Orbscan II TM.
ABSTRACT

PURPOSE:

To evaluate an artificial neural network in order to correctly identify Orbscan II TM tests of patients with normal and keratoconus corneas.

METHODS:

A retrospective analysis included 98 Orbscan II TM tests of 59 subjects and an artificial neural network was created and trained based on the Java Neural Network 1.1 software. Seventy-three tests (59 normal tests and 14 keratoconus examinations) were applied to train the neural network and 25 eyes were used to test the method (19 normal eyes and 6 cases of keratoconus corneas).

RESULTS:

Backpropagation method was performed to train the neural network to 5 percent error and 0.2 learning rate. The trained neural network presented sensibility and specificity of 83 and 100 percent respectively.

CONCLUSION:

Artificial neural network can accurately help clinicians to classify keratoconus in Orbscan II TM tests.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Neural Networks, Computer / Corneal Topography / Keratoconus Type of study: Diagnostic study / Observational study / Prognostic study Limits: Humans Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade de Tecnologia e Ciências/BR / USP/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Neural Networks, Computer / Corneal Topography / Keratoconus Type of study: Diagnostic study / Observational study / Prognostic study Limits: Humans Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2008 Type: Article Affiliation country: Brazil Institution/Affiliation country: Faculdade de Tecnologia e Ciências/BR / USP/BR / Universidade de São Paulo/BR