Your browser doesn't support javascript.
loading
Penile torsion correction by diagonal corporal plication sutures
Snow, Brent W.
  • Snow, Brent W; University of Utah. Division of Urology. Salt Lake. US
Int. braz. j. urol ; 35(1): 56-59, Jan.-Feb. 2009. ilus
Article in English | LILACS | ID: lil-510263
ABSTRACT
Penile torsion is commonly encountered. It can be caused by skin and dartos adherence or Buck’s fascia attachments. The authors suggest a new surgical approach to solve both problems. If Buck’s fascia involvement is demonstrated by artificial erection then a new diagonal corporal plication suture is described to effectively solve this problem.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Penile Diseases / Torsion Abnormality / Suture Techniques / Fascia Limits: Humans / Male Language: English Journal: Int. braz. j. urol Journal subject: Urology Year: 2009 Type: Article Affiliation country: United States Institution/Affiliation country: University of Utah/US

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Penile Diseases / Torsion Abnormality / Suture Techniques / Fascia Limits: Humans / Male Language: English Journal: Int. braz. j. urol Journal subject: Urology Year: 2009 Type: Article Affiliation country: United States Institution/Affiliation country: University of Utah/US