Evaluación físico-química del agua de depósitos positivos a focos de Aedes aegypti / Physico-chemical evaluation of the water from reservoirs positive to Aedes aegypti foci
Sardiñas Peña, Olivia; García Melían, Maricel; Castillo, Ibian; Fernández Novo, Marta.
  • Sardiñas Peña, Olivia; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. CU
  • García Melían, Maricel; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. CU
  • Castillo, Ibian; Centro Municipal de Higiene y Epidemiología del Cotorro. La Habana. CU
  • Fernández Novo, Marta; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. CU
Rev. cuba. hig. epidemiol ; 46(2)mayo-sept. 2008. tab, graf
Article in Spanish | LILACS | ID: lil-515721
RESUMEN
Objetivo: realizar la evaluación físico-química del agua de depósitos positivos a focos de Aedes aegypti en el municipio Cotorro de Ciudad de La Habana. Métodos: el muestreo se realizó en el periodo de junio de 2004 a julio de 2005. El universo de trabajo estuvo constituído por 86 focos de Aedes aegypti confirmados en el laboratorio del Centro Municipal de Higiene y Epidemiología, donde existieron más de 500 mL de agua en áreas de riesgo definidas por el Departamento de Lucha Antivectorial del municipio. Resultados: los focos representaron 41,3 por ciento del total de focos identificados en las 3 áreas de salud. La muestra recolectada representó 32,5 por ciento del total de focos. El pH se mantuvo en un intervalo de 6,80-7,11, la turbidez entre 5,0-7,8 U y la conductividad entre 406-909 µS/cm. Se encontró que la concentración de nitrato estuvo entre 6,25-14,26 mg/L y la del nitrito entre < 0,006-3,62 mg/L. Conclusiones: la evaluación de las características físico-químicas, pH, turbiedad y nitratos del agua de depósitos positivos a focos de Aedes aegypti no sobrepasan los valores establecidos en la norma cubana. La concentración de nitrito sobrepasa la norma cubana en 17,8 por ciento de las muestras.
ABSTRACT
Aim: to perform the physical-chemical evaluation of the reservoirs positive to Aedes aegypti foci in Cotorro municipality, Havana City. Methods: the sampling was carried out from june 2004 to july 2005. The universe included 86 foci of Aedes aegypti confirmed in the laboratory of the Municipal Centre of Hygiene and Epidemiology, where there were more than 500 mL of water in risk areas, defined by the Municipal Department of Antivectorial Fight. Results: the foci accounted for 41.3 percent of all the foci identified in the 3 health areas. The collected sample represented 32.5 percent of all foci. pH remained in an interval of 6.80-7.11, turbidity was between 5.0-7.8 U, and conductivity was between 406-909 µS/cm. It was found that the concentration of nitrate was between 6.25-14.26 mg/L, and that of nitrite between < 0.006-3.62 mg/L. Conclusions: the evaluation of physical-chemical features, pH, turbidity, and nitrates in reservoirs positive to Aedes aegypti foci did not exceed the values established in the cuban standard. The nitrite concentration surpassed the cuban standard in 17.8 percent of all samples.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Water Quality / Aedes Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. cuba. hig. epidemiol Journal subject: Public Health Year: 2008 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro Municipal de Higiene y Epidemiología del Cotorro/CU / Instituto Nacional de Higiene, Epidemiología y Microbiología/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Water Quality / Aedes Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Rev. cuba. hig. epidemiol Journal subject: Public Health Year: 2008 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro Municipal de Higiene y Epidemiología del Cotorro/CU / Instituto Nacional de Higiene, Epidemiología y Microbiología/CU