Efeitos de técnicas de desobstrução brônquica na mecânica respiratória de neonatos prematuros em ventilação pulmonar mecânica / Results of airway clearance techniques in respiratory mechanics of preterm neonates under mechanical ventilation
Santos, Mara Lisiane de Moraes dos; Souza, Lais Alves de; Batiston, Adriane Pires; Palhares, Durval Batista.
  • Santos, Mara Lisiane de Moraes dos; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Souza, Lais Alves de; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Batiston, Adriane Pires; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Palhares, Durval Batista; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
Rev. bras. ter. intensiva ; 21(2): 183-189, abr.-jun. 2009. tab
Article in English, Portuguese | LILACS | ID: lil-521498
RESUMO

OBJETIVOS:

O objetivo do trabalho foi avaliar as repercussões de técnicas fisioterapêuticas específicas na resistência média de vias aéreas e na complacência dinâmica de neonatos pré-termo em ventilação pulmonar mecânica.

MÉTODOS:

Dezoito neonatos pré-termo em ventilação pulmonar mecânica convencional foram submetidos a uma sessão de fisioterapia respiratória (compressão torácica manual durante a expiração + aspiração da cânula intratraqueal). Medidas de resistência média de vias aéreas e complacência dinâmica foram realizadas antes, 10, 40 e 70 minutos após as intervenções, por meio de um pneumotacógrafo com monitor gráfico (NewPort Navigator GM-250®), acoplado a um transdutor de fluxo (Varfley-Bicore®). Para análise dos resultados, os neonatos pré-termo foram divididos em dois grupos tempo de ventilação pulmonar mecânica <5 dias e ventilação pulmonar mecânica >5 dias. Os resultados foram analisados pelo teste Friedman e pós-teste de Dunn de múltiplas comparações (p<0,05 significante).

RESULTADOS:

Observou-se no grupo ventilação pulmonar mecânica <5 redução significativa da resistência média de vias aéreas no 10º minuto após a intervenção (p<0,05), sem alterações significativas na complacência dinâmica. No grupo ventilação pulmonar mecânica >5 dias a resistência média de vias aéreas reduziu no 10º(p<0,001), 40º(p<0,05) e 70º(p<0,05) minutos após a intervenção. A complacência dinâmica melhorou significativamente no 10º minuto (p<0,05).

CONCLUSÕES:

As técnicas para aumento do transporte de secreção traqueobrônquica utilizadas beneficiaram a resistência média de vias aéreas e complacência dinâmica dos neonatos estudados em ventilação pulmonar mecânica >5 dias, com melhores respostas na resistência média de vias aéreas.
ABSTRACT

OBJECTIVES:

This research aimed to evaluate the repercussions of specific chest physiotherapy procedures in mean airway resistance and in dynamic compliance in preterm infants in mechanical ventilation.

METHODS:

Eighteen preterm infants in conventional mechanical ventilation were submitted to one session of chest physiotherapy (manual chest compression during expiration + intermittent aspiration of intratracheal cannula). Mean airway resistance and dynamic compliance measurements were taken prior to, 10, 40 and 70 minutes after intervention using a pneumotachograph with graphic display (Newport Navigator GM-250®), coupled to a flow transducer (Varfley-Bicore®). For analysis of results the infants were divided into 2 groups; less than 5 days (group mechanical ventilation <5) and 5 days or more (group mechanical ventilation >5) on mechanical ventilation. Values were analyzed by Friedman Test, with Dunn's Multiple Comparisons Test (p<0,05 significant).

RESULTS:

In group mechanical ventilation <5 a significant reduction of mean airway resistance was observed at the 10th minute after intervention (p<0,05). There were no significant alterations in dynamic compliance. The group mechanical ventilation >5 mean airway resistance had a significant reduction at the 10th (p<0,001), 40th (p<0,05) and 70th (p<0,05) minute after intervention. The dynamic compliance improved significantly only at the 10th minute (p<0,05).

CONCLUSIONS:

The airway clearance techniques used in preterm neonates under conventional mechanical ventilation >5 improved mean airway resistance and dynamic compliance, with best results for the mean airway resistance.

Full text: Available Index: LILACS (Americas) Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Mato Grosso do Sul/BR