Relação entre diâmetro e conicidade de instrumentos rotatórios de níquel-titânio na resistência à fratura por torção / The relationship between diameter and taper of nickel-titanium rotary instruments on the torsional resistance to fracture
RGO (Porto Alegre)
;
57(2): 193-197, abr.-jun. 2009. ilus, tab
Article
in Portuguese
| LILACS, BBO
| ID: lil-522795
RESUMO
Objetivo:
Avaliar a resistência à fratura por torção de limas rotatórias de níquel-titânio com diferentes diâmetros e conicidades.Métodos:
Foram utilizados instrumentos Profile (Dentsply Maillerfer, Ballaigues, Suíça) nos diâmetros de 15 a 40 e nas conicidades 0.04 e 0.06. Dez instrumentos de cada diâmetro e conicidade foram testados totalizando cento e vinte limas. O torque máximo (Tmax), até a fratura, foi determinado de acordo com o protocolo no. 28 da American National Standards Institute/American Dental Association. A força máxima era convertida em torque máximo através da fórmula Tmax = Cargamax x Raio.Resultados:
O diâmetro (p<0,001) e a conicidade (p<0,001) influenciaram no torque máximo até a fratura. Com o aumento do diâmetro e da conicidade houve um aumento progressivo do torque. Com o teste da regressão múltipla foi possível estabelecer uma equação relacionando o torque máximo em função do diâmetro (D) e da conicidade (C) Tmax = -1.4 + 0.08D + 10.5C.Conclusão:
O aumento do diâmetro e da conicidade promoveu uma ampliação da resistência à fratura por torção. A variação da conicidade de 0.04 para 0.06, em instrumentos com o mesmo diâmetro, elevou em torno de 25% a resistência à fratura por torção.ABSTRACT
Objective:
To evaluate the resistance to fracture of rotary Ni-Ti files of various diameters and tapers after torsional stress simulation.Methods:
Profile (Dentsply Maillerfer, Ballaigues, Suíça) instruments sizes 15 to 40, taper 0.04 and 0.06 were used. Ten instruments of each size and taper were tested, totaling 120 files. The maximum torque (Tmax) until fracture was determined in accordance with the ANSI / ADA Protocol Nº 28 . The maximum force was converted into maximum torque using the formula Tmax = Loadmax x RadiusResults:
The diameter (p<0.001) and taper (p<0.001) influenced the maximum torque to fracture. With the increase in diameter and taper there was a gradual increase in the maximum torque. Using the multiple regression method an equation relating the maximum torque to the diameter (D) and the taper (T) was found Tmax = -1.4 + 0.08D + 10.5T.Conclusion:
The increase in diameter and taper promoted an increase in resistance to torsion. The variation of the taper from 0.04 to 0.06 in instruments with the same diameter increased resistance to fracture by torsion by around 25%.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Torque
/
Endodontics
Type of study:
Evaluation studies
Language:
Portuguese
Journal:
RGO (Porto Alegre)
Journal subject:
Dentistry
Year:
2009
Type:
Article
Affiliation country:
Brazil
Institution/Affiliation country:
Centro Universitário do Maranhão/BR
/
Universidade Estadual Paulista Júlio de Mesquita Filho/BR