Influência da distância intereletrodos e da cadência de movimento no domínio da frequência do sinal de EMG de superfície / Influence of the inter-electrodes distance and cadence of movement in the surface EMG signal frequency domain
Tank, Flávia Fernandes; Silva, Gustavo Telles da; Oliveira, Carlos Gomes de; Garcia, Marco Antonio Cavalcanti.
  • Tank, Flávia Fernandes; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica. BR
  • Silva, Gustavo Telles da; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica. BR
  • Oliveira, Carlos Gomes de; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica. BR
  • Garcia, Marco Antonio Cavalcanti; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Laboratório de Biomecânica. BR
Rev. bras. med. esporte ; 15(4): 272-276, jul.-ago. 2009. ilus, graf
Article in Portuguese | LILACS | ID: lil-526428
RESUMO
A eletromiografia de superfície (sEMG), apesar de amplamente utilizada em investigações biomecânicas, ainda apresenta inúmeros questionamentos sobre a influência das distâncias intereletrodos (DIE) na morfologia do sinal, principalmente em contrações isotônicas. Logo, muitos dos trabalhos desenvolvidos ainda se limitam ao âmbito do laboratório de pesquisa, onde é possível estabelecer maior controle nos protocolos de registro e análise, o que não é comumente observado na prática clínico-desportiva. Dessa forma, o objetivo do estudo foi examinar os efeitos de dois protocolos de colocação de eletrodos e a realização de contrações isotônicas no domínio da frequência do sinal de sEMG. Quinze sujeitos do sexo masculino (idade 22,8 ± 3,5 anos), todos destros, realizaram contrações dinâmicas do bíceps braquial direito com carga estimada em 20 por cento da contração voluntária máxima em três diferentes cadências (30, 45, 60bpm). Os sinais de sEMG foram registrados por meio de dois canais, cujas DIEs foram de 4,2 e 13cm, respectivamente. A avaliação dos sinais de sEMG foi baseada na frequência mediana do espectro de potencial do sinal, calculado via transformada rápida de Fourier. A DIE e a cadência foram definidas como fatores (ANOVA two-way; α = 0,05). Não foram observadas diferenças estatísticas e qualquer interação entre ambos os fatores nas três cadências (P > 0,05). Sugere-se que, independentemente da distância utilizada entre os eletrodos, uma investigação no domínio da frequência do sinal de sEMG em tarefas dinâmicas seja evitada, mesmo a partir de DIEs reduzidas, como é sugerido pela literatura, dado que variações no torque e no comprimento muscular podem corromper o sinal e, portanto, sua interpretação.
ABSTRACT
Surface electromyography (SEMG), despite being widely used in biomechanical investigations, still presents massive questioning about the influence of the distance of the inter-electrodes (DIE) in the signal morphology, especially in isotonic contractions. Thus, much of the research developed is still limited to the laboratory, where it is possible to establish better control over the recording and analysis protocols, which is not commonly observed in the clinical-sportive practice. Therefore, the aim of this study was to examine the effects of two electrodes placement protocols and the performance of isotonic contractions in the SEMG sign frequency domain. Fifteen right-handed male subjects (aged 22.8 ± 3.5 years) performed dynamic contractions of the right brachial biceps with load estimated in 20 percent of the maximum voluntary contraction in three different cadences (30, 45 and 60 bpm). The SEMG signals were registered by two channels with DIEs of 4.2 and 13 cm, respectively. The SEMG signals assessment was based on the median frequency of the potential spectrum of the signal, calculated via fast Fourier transform. DIE and cadence were defined as factors (two-way ANOVA; α = 0.05). No statistical differences or any interaction between both factors were observed in the three cadences (P> 0.05). Regardless of the distance used between electrodes, an investigation in the SEMG signal frequency domain in dynamic tasks should be avoided, even from reduced DIEs, as suggested in the literature, since variations in the torque and muscular length may disrupt the signal and hence its interpretation.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Arm / Signal Processing, Computer-Assisted / Analysis of Variance / Muscle, Skeletal / Electrodes / Electromyography / Isotonic Contraction Type of study: Diagnostic study / Practice guideline / Screening study Limits: Humans / Male Language: Portuguese Journal: Rev. bras. med. esporte Journal subject: Sports Medicine Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Arm / Signal Processing, Computer-Assisted / Analysis of Variance / Muscle, Skeletal / Electrodes / Electromyography / Isotonic Contraction Type of study: Diagnostic study / Practice guideline / Screening study Limits: Humans / Male Language: Portuguese Journal: Rev. bras. med. esporte Journal subject: Sports Medicine Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio de Janeiro/BR