Avaliação da percepção da fala no ruído em diferentes posições em adultos com implante coclear / Evaluation of the speech perception in the noise in different positions in adults with cochlear implants
Santos, Karlos Thiago Pinheiro dos; Fernandes, João Cândido; Amorim, Raquel Beltrão; Bevilacqua, Maria Cecília.
  • Santos, Karlos Thiago Pinheiro dos; Universidade de São Paulo. Hospital de Reabilitação de Anomalias Craniofaciais. Bauru. BR
  • Fernandes, João Cândido; Universidade Estadual Paulista Júlio de Mesquita Filho. BR
  • Amorim, Raquel Beltrão; Instituto de Comunicação e Audição. ALFA. Bauru. BR
  • Bevilacqua, Maria Cecília; Universidade de São Paulo. Departamento de Fonoaudiologia. BR
Arq. int. otorrinolaringol. (Impr.) ; 13(1): 16-23, jan.-mar. 2009. tab, graf
Article in English, Portuguese | LILACS | ID: lil-529410
RESUMO
Introdução: A queixa mais frequente dos usuários de implante coclear tem sido reconhecer e compreender o sinal da fala na presença do ruído. Pesquisas investigam a percepção da fala dos usuários de implante coclear, enfocando aspectos como os efeitos da diminuição da relação sinal/ruído na percepção da fala, o reconhecimento da fala no ruído, com diferentes tipos de implante coclear e estratégias de codificação da fala e os efeitos da estimulação biaural na percepção da fala no ruído. Objetivo: 1 - Avaliar a percepção de fala em adultos usuários de implante coclear, em diferentes posições quanto à apresentação do estimulo; 2 - comparar os índices de reconhecimento de fala nas posições frontal, ipsilateral e contralateral e 3 - analisar o efeito da adaptação monoaural na percepção da fala com ruído. Método: Avaliados 22 adultos usuários de implante coclear quanto à percepção da fala. Os indivíduos foram submetidos à avaliação de reconhecimento das sentenças, com ruído competitivo na relação sinal/ruído +10 decibeis em três posições: frontal, ipsilateral e contralateral ao lado implantado. Resultados: Os resultados demonstraram maior índice de reconhecimento da fala na posição ipsilateral (100%) e o menor índice de reconhecimento da fala com sentenças na posição contralateral (5%). Conclusão: O desempenho da percepção da fala em indivíduos implantados é prejudicado quando é introduzido o ruído competitivo, o índice de reconhecimento da fala é melhor quando a fala é apresentada ipsilateralmente, e consequentemente é pior quando é apresentada contralateralmente ao implante coclear, e há maior prejuízo na inteligibilidade da fala quando existe apenas entrada monoaural.
ABSTRACT
Introduction: The most frequent complaint of the cochlear implant users has been to recognize and understand the speech signal in the presence of noise. Researches have been developed on the speech perception of users of cochlear implant with focus on aspects such as the effect of the reduction to the signal/noise ratio in the speech perception, the speech recognition in the noise, with different types of cochlear implant and strategies of speech codification and the effects of the binaural stimulation in the speech perception in noise. Objective: 1-To assess the speech perception in cochlear implant adult users in different positions regarding the presentation of the stimulus, 2-to compare the index of speech recognition in the frontal, ipsilateral and contralateral positions and 3-to analyze the effect of monoaural adaptation in the speech perception with noise. Method: 22 cochlear implant adult users were evaluated regarding the speech perception. The individuals were submitted to sentences recognition evaluation, with competitive noise in the signal/noise ratio +10 decibels in three positions: frontal, ipsilateral and contralateral to the cochlear implant side. Results: The results demonstrated the largest index of speech recognition in the ipsilateral position (100%) and the lowest index of speech recognition with sentences in the contralateral position (5%). Conclusion: The performance of speech perception in cochlear implant users is damaged when the competitive noise is introduced, the index of speech recognition is better when the speech is presented ipsilaterally, and it's consequently worse when presented contralaterally to the cochlear implant, and there are more damages in the speech intelligibility when there is only monoaural input.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Speech Perception / Adult / Cochlear Implantation / Hearing Loss / Noise Limits: Adolescent / Adult / Female / Humans / Male Language: English / Portuguese Journal: Arq. int. otorrinolaringol. (Impr.) Journal subject: Otolaryngology Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto de Comunicação e Audição/BR / Universidade Estadual Paulista Júlio de Mesquita Filho/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Speech Perception / Adult / Cochlear Implantation / Hearing Loss / Noise Limits: Adolescent / Adult / Female / Humans / Male Language: English / Portuguese Journal: Arq. int. otorrinolaringol. (Impr.) Journal subject: Otolaryngology Year: 2009 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto de Comunicação e Audição/BR / Universidade Estadual Paulista Júlio de Mesquita Filho/BR / Universidade de São Paulo/BR