Your browser doesn't support javascript.
loading
Correlação entre peso fetal estimado por ultrassonografia e peso neonatal / Correlation between estimated fetal weight by ultrasound and neonatal weight
Freire, Djacyr Magna Cabral; Cecatti, José Guilherme; Paiva, Cláudio Sérgio Medeiros.
  • Freire, Djacyr Magna Cabral; Universidade Estadual de Campinas. Campinas. BR
  • Cecatti, José Guilherme; Universidade Estadual de Campinas. Faculdade de Ciências Médicas. Departamento de Tocoginecologia. Campinas. BR
  • Paiva, Cláudio Sérgio Medeiros; Universidade Federal da Paraíba. Departamento Materno-Infantil. João Pessoa. BR
Rev. bras. ginecol. obstet ; 32(1): 4-10, jan. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-539137
RESUMO
OBJETIVO: avaliar a correlação entre o peso fetal estimado (PFE) por ultrassonografia e o peso neonatal (PN), bem como a capacidade do PFE predizer as alterações do PN entre gestantes de João Pessoa (PB). MÉTODOS: estudo de validação diagnóstica incluindo 122 gestantes que tiveram o PFE calculado por ultrassonografia até sete dias antes do parto e o PN determinado imediatamente após o nascimento, com balança específica para recém-nascidos. A correlação entre o PFE e o PN foi avaliada pelo coeficiente de correlação de Pearson entre as duas medidas e pela média das diferenças entre elas. O PFE e o PN foram classificados em: pequeno para idade gestacional (PIG), adequado para a idade gestacional (AIG) e grande para a idade gestacional (GIG), de acordo com os percentis 10 e 90 das respectivas curvas de referência. O diagnóstico de desvios do PFE foi validado utilizando a curva de valores de referência de peso neonatal de Alexander como padrão-ouro, estimando-se a sensibilidade, especificidade, valores preditivos positivo e negativo. RESULTADOS: houve uma elevada correlação linear entre o PFE e o PN (R=0,96) e a diferença entre eles variou entre -474 g e +480 g, com média de +3 g. A maioria das máximas variações percentuais da estimativa de peso esteve entre 10 e 15 por cento. O PFE teve sensibilidade de 85,7 por cento e especificidade de 100 por cento para detecção de PIG, e de 100 e 77,2 por cento, respectivamente, para GIG. CONCLUSÕES: o PFE é capaz de predizer adequadamente o PN, e a curva de PFE de referência testada teve bom desempenho no rastreamento dos desvios do crescimento fetal, quando utilizada nessa população.
ABSTRACT
PURPOSE: to evaluate the correlation between the estimated fetal weight (EFW) by ultrasonography and the neonatal weight (NW), as well as the EFW's capacity to predict changes in NW among pregnant women in João Pessoa, Paraíba, Brazil. METHODS: a diagnostic validation study, including 122 pregnant women who have had the EFW calculated by ultrasonography up to seven days before delivery and the NW established immediately after birth, with a specific newborn's scale. The correlation between EFW and NW measurements was assessed by Pearson's correlation coefficient and by the mean difference between them. EFW and NW were classified as: low for the gestational age (LGA), adequate for the gestational age (AGA) and high for the gestational age (HGA), according to the percentiles 10 and 90 of the respective reference curves. The diagnosis of EFW deviation has been validated using the values of the Alexander's NW reference curve as gold-standard, by estimating the sensitivity, specificity, and positive and negative predictive values. RESULTS: there has been a high linear correlation between the EFW and NW (R=0.96), and the difference between them has varied from -474 g to +480 g, with an average of +3 g. Most of the highest percent weight estimate variations were between 10 and 15 percent. EFW has had 85.7 percent of sensitivity and 100 percent of specificity for the detection of LGA, and 100 and 77.2 percent, respectively, for the detection of HGA. CONCLUSIONS: EFW is able to predict NW adequately, and the reference EFW tested has had a good performance in the screening of fetal growth deviation, in the population studied.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Birth Weight / Ultrasonography, Prenatal / Fetal Weight Type of study: Diagnostic study Limits: Adolescent / Adult / Female / Humans / Infant, Newborn / Pregnancy Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR / Universidade Federal da Paraíba/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Birth Weight / Ultrasonography, Prenatal / Fetal Weight Type of study: Diagnostic study Limits: Adolescent / Adult / Female / Humans / Infant, Newborn / Pregnancy Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR / Universidade Federal da Paraíba/BR