Your browser doesn't support javascript.
loading
Estratégias para redução da exposição de radiação ionizante em mulheres submetidas à embolização de miomas uterinos / Strategies for reduction of exposure to ionizing radiation in women undergone to uterine fibroid embolization
Affonso, Breno Boueri; Nasser, Felipe; Silva, Seleno Glauber de Jesus; Silva, Márcia Carvalho; Zlotnik, Eduardo; Messina, Marcos de Lorenzo; Baracat, Edmund Chada.
  • Affonso, Breno Boueri; Hospital Israelita Albert Einstein. São Paulo. BR
  • Nasser, Felipe; Hospital Israelita Albert Einstein. São Paulo. BR
  • Silva, Seleno Glauber de Jesus; Hospital Israelita Albert Einstein. São Paulo. BR
  • Silva, Márcia Carvalho; Hospital Israelita Albert Einstein. São Paulo. BR
  • Zlotnik, Eduardo; Hospital Israelita Albert Einstein. São Paulo. BR
  • Messina, Marcos de Lorenzo; Hospital Israelita Albert Einstein. São Paulo. BR
  • Baracat, Edmund Chada; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. São Paulo. BR
Rev. bras. ginecol. obstet ; 32(2): 77-81, fev. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-540258
RESUMO

OBJETIVO:

quantificar a dose de radiação ionizante absorvida pelo ovário e pela pele em pacientes submetidas à embolização de miomas uterinos (EMUT), assim como sugerir um protocolo radiológico voltado à redução dos riscos envolvidos neste procedimento.

MÉTODOS:

setenta e três mulheres consecutivas (média etária de 27 anos), participantes de protocolo de pesquisa institucional, portadoras de miomas uterinos sintomáticos com indicação de tratamento minimamente invasivo, foram submetidas a procedimento de EMUT. Foram calculadas a estimativa de radiação absorvida pelos ovários por meio de dosímetros vaginais e a estimativa de dose de entrada na pele, por cálculos indiretos de absorção de radiação. As primeiras 49 pacientes fizeram parte do Grupo Pré-alteração e as últimas 24, do Grupo Pós-alteração. O segundo grupo recebeu um protocolo modificado de imagem radiológica, com redução pela metade do número de quadros por segundo durante as arteriografias, idealizado na tentativa de enquadrar os valores obtidos aos existentes na literatura, assim como foi evitado ao máximo a exposição desnecessária ao feixe de raios X.

RESULTADOS:

não houve complicações técnicas em nenhum dos procedimentos realizados. Não houve diferenças entre o tempo médio de fluoroscopia ou entre o número médio de arteriografias entre os dois grupos. Foi obtida uma redução de 57 por cento na estimativa de dose ovariana absorvida entre as pacientes dos dois grupos (29,0 versus 12,3 cGy), assim como uma redução de 30 por cento na estimativa de dose absorvida pela pele (403,6 versus 283,8 cGy).

CONCLUSÕES:

a redução significativa da absorção de radiação em pacientes submetidas a procedimentos de EMUT pode ser alcançada pela modificação do número de quadros por segundo nas aquisições arteriográficas, assim como pela implantação rotineira das normas de proteção radiológica.
ABSTRACT

PURPOSE:

to determine the dose of ionizing radiation absorbed by the ovaries and the skin of patients undergoing uterine fibroid embolization (UFE), and to suggest a radiologic protocol directed at reducing the risks involved in this procedure.

METHODS:

seventy-three consecutive women (mean age 27 years) participating in an institutional research protocol, having symptomatic uterine fibroids with indication for minimally invasive treatment, underwent UFE. We estimated the radiation absorbed by the ovaries by means of vaginal dosimeters and the radiation dose absorbed by the skin by means of indirect calculations of radiation absorption. The first 49 patients belonged to the Pre-modification Group, and the last 24, to the Post-modification Group. The second group received a modified protocol of X-ray imaging, with a reduction by half of the frames number per second during arteriography, in an attempt to match the values obtained to those of the literature, and avoiding as much as possible unnecessary exposure to the X-ray beam.

RESULTS:

there were no technical complications in any of the procedures performed. There were no differences in the mean fluoroscopy time or in the mean number of arteriographies between the two groups. We obtained a 57 percent reduction in the estimated absorbed ovarian dose between groups (29.0 versus 12.3 cGy) and a 30 percent reduction in the estimated dose absorbed by the skin (403.6 versus 283.8 cGy).

CONCLUSIONS:

a significant reduction in the absorption of radiation in patients undergoing UFE can be achieved by changing the number of frames per second in angiographic series, and by the routine use of radiological protection standards.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Radiation Dosage / Uterine Neoplasms / Embolization, Therapeutic / Leiomyoma Type of study: Practice guideline Limits: Adult / Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Israelita Albert Einstein/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Radiation Dosage / Uterine Neoplasms / Embolization, Therapeutic / Leiomyoma Type of study: Practice guideline Limits: Adult / Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Israelita Albert Einstein/BR / Universidade de São Paulo/BR