RESUMO
Justificativa e

objetivos:

Para determinar o nível vertebral para punção lombar, utiliza-se uma linha imaginária que une as cristas ilíacas. Essa linha cruza a coluna vertebral no nível L4 ou no espaço L4-L5. Essa referência anatômica pode ser inexata em grande proporção de pacientes. Este estudo teve como objetivo determinar se há diferença na determinação do espaço vertebral L3-L4 pelo exame físico quando comparado ao ultrassom em gestantes obesas e não obesas.

Método:

Foram estudadas pacientes adultas submetidas à cesariana eletiva sob raquianestesia. As pacientes foram analisadas em dois grupos obesas e não obesas. Com a paciente na posição sentada, foi determinado pelo exame físico o espaço vertebral L3-L4. Em seguida, foi executada a ultrassonografia da região lombar. Houve a identificação do osso sacro e o transdutor foi dirigido em direção cranial para identificar os processos espinhosos das vértebras lombares. Foi registrado qual nível vertebral havia sido estimado clinicamente como L3-L4.

Resultados:

Foram incluídas 90 pacientes, sendo 43 não obesas e 47 obesas. Em todas as pacientes, foi possível a determinação dos espaços vertebrais lombares por meio da ultrassonografia. Os espaços vertebrais identificados como L3-L4 ao exame físico corresponderam aos estimados como L3-L4 pelo ultrassom em 53 por cento e 49 por cento nos grupos não obesas e obesas, respectivamente. Não houve diferença significativa entre os grupos.

Conclusões:

As percentagens de acerto na identificação do espaço vertebral L3-L4 em gestantes obesas e não obesas são baixas. A ultrassonografia da coluna vertebral pode reduzir o erro de determinação do espaço vertebral L3-L4 em gestantes obesas e não obesas.
ABSTRACT
Background and

objectives:

An imaginary line connecting both iliac crests is used to determine the vertebral level for lumbar puncture. This line crosses the spine at the level of L4 or the L4-L5 space. This anatomical reference can be inaccurate in a large proportion of patients. The objective of the present study was to determine whether the identification of the L3-L4 space by the physical exam differs from that of the ultrasound in obese and non-obese pregnant women.

Methods:

Adult patients undergoing elective cesarean sections under spinal block participated in this study. Patients were divided in two groups obese and non-obese. The L3-L4 space was determined by physical exam with the patient in the sitting position. This was followed by a lumbar ultrasound. After the sacrum was identified, the transducer was directed in the cephalad direction to identify the spinous processes of the lumbar vertebrae. The clinically estimated L3-L4 level was recorded.

Results:

Ninety patients, 43 obese and 47 non-obese, were included in this study. Lumbar intervertebral spaces were identified by ultrasound in all patients. The L3-L4 space clinically identified corresponded to the ultrasound identification in 53 percent and 49 percent of the cases in the non-obese and obese groups, respectively. There was no significant difference between groups.

Conclusions:

The L3-L4 space is correctly identified in a low percentage of obese and non-obese pregnant women. Spinal ultrasound can reduce the incidence of mistaken identification of the L3-L4 space in obese and non-obese pregnant women.
RESUMEN
Justificativa y

objetivos:

Para determinar el nivel vertebral para la punción lumbar, se utiliza una línea imaginaria que une las crestas ilíacas. Esa línea cruza la columna vertebral en el nivel L4 o en el espacio L4-L5. Esa referencia anatómica puede ser inexacta en una gran proporción de pacientes. Este estudio quiso determinar si existe alguna diferencia en la determinación del espacio vertebral L3-L4 por el examen físico cuando se le comparó al ultrasonido en embarazadas obesas y no obesas.

Método:

Se estudiaron pacientes adultas sometidas a la cesárea electiva bajo raquianestesia. Las pacientes se analizaron en dos grupos obesas y no obesas. Con la paciente en la posición sentada, se determinó a través del examen físico, el espacio vertebral L3-L4. Enseguida se realizó el ultrasonido de la región lumbar. Se identificó el hueso sacro y el transductor fue colocado en dirección craneal para identificar los procesos espinosos de las vértebras lumbares. Quedó registrado el nivel vertebral que había sido estimado clínicamente como L3-L4.

Resultados:

Se incluyeron 90 pacientes, siendo 43 no obesas y 47 obesas. En todas las pacientes se pudieron determinar los espacios vertebrales lumbares a través del ultrasonido. Los espacios vertebrales identificados como L3-L4 en el examen físico, correspondieron a los estimados como L3-L4 por el ultrasonido en un 53 y un 49 por ciento en los grupos de no obesas y obesas, respectivamente. No hubo diferencia significativa entre los grupos.

Conclusiones:

El porcentaje de acierto en la identificación del espacio vertebral L3-L4 en embarazadas obesas y no obesas es bajo. El ultrasonido de la columna vertebral puede reducir el error de determinación del espacio vertebral L3-L4 en embarazadas obesas y no obesas.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Spinal Puncture / Ultrasonics / Anesthesia, Conduction / Anesthesia, Spinal / Obesity Limits: Female / Humans / Pregnancy Language: English / Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Catarina/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Spinal Puncture / Ultrasonics / Anesthesia, Conduction / Anesthesia, Spinal / Obesity Limits: Female / Humans / Pregnancy Language: English / Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Santa Catarina/BR