Avaliação in vitro do emprego de retificadores de cilindros fundidos na adaptação de próteses implanto suportadas / In vitro evaluation of cast cylinders rectifiers in the marginal misfit of implant-supported prosthesis
Akama, Cristina Mydoli; Vasconcellos, Diego Klee de; Jóias, Renato Morales; Balducci, Ivan; Bottino, Marco Antonio.
  • Akama, Cristina Mydoli; s.af
  • Vasconcellos, Diego Klee de; Universidade Federal de Santa Catarina. Centro de Ciências da Saúde. Departamento de Estomatologia. Florianópolis. BR
  • Jóias, Renato Morales; Universidade Metodista de São Paulo. São Bernardo do Campo. BR
  • Balducci, Ivan; Universidade Estadual Paulista. Faculdade de Odontologia de São José dos Campos. Departamento de Odontologia Social e Clínica Infantil. São José dos Campos. BR
  • Bottino, Marco Antonio; Universidade Estadual Paulista. Faculdade de Odontologia de São José dos Campos. Departamento de Materiais Odontológicos e Prótese. São José dos Campos. BR
Odonto (Säo Bernardo do Campo) ; 16(31): 9-18, jan.-jun. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-542821
RESUMO
Avaliou-se a interface de assentamento de cilindros fundidos em ligas não preciosas a pilares protéticos implanto-suportados, após o uso de retificadores desenvolvidos para reduzir a desadaptação marginal de fundições. A investigação foi realizada com dois grupos de componentes Esteticone e Micro-Unit, fundidos em liga de Ni-Cr (Wiron 99,) e Co-Cr (Wirobond C), pela técnica convencional (maçarico) e por indução em alta freqüência. Cilindros usinados em ouro foram empregados como padrões de referência. As mensurações das desadaptações marginais dos cilindros fundidos foram realizadas com auxílio de microscópio óptico em dois momentos, antes e após o uso de retificadores de cilindros. Para os componentes usinados em ouro, a leitura foi efetuada em um único momento, pois não houve retifica destes componentes. Os valores de desadaptação dos cilindros fundidos foram submetidos à análise estatística utilizando-se ANOVA (3-fatores) e Teste de Tukey (a 5%). Comparações entre cilindros fundidos retificados e cilindros usinados foram realizadas com Teste t de Student para amostras não pareadas. A redução da desadaptação marginal foi estatisticamente significante (p< 0,05) para componentes fundidos em Ni-Cr. Para os cilindros fundidos em Co-Cr, os retificadores não determinaram importantes modificações em todos os grupos testados. Os menores valores de desajuste marginal foram registrados para componentes Micro Unit fundidos convencionalmente (maçarico) em Ni-Cr após a retífica (29,08mm). A desadaptação registrada para este grupo foi estatisticamente semelhante (p> 0,05) à obtida com componentes similares usinados em ouro (22,44mm). Concluiu-se que o uso de retificadores manuais de cilindros fundidos determinou expressiva redução de desadaptação marginal em componentes fundidos, principalmente com liga metálica de Ni-Cr.
ABSTRACT
This study evaluated the fitting interface of cylinders cast in non-precious alloys to implant-supported prosthetic abutments, after utilization of rectifiers designed to reduce the marginal misfit of cast cylinders. Two groups of components were investigated, namely Esteticone (Est) and Micro-Unit (MU), cast in Ni-Cr alloy (Wiron 99) and Co-Cr (Wirobond C), by the conventional technique (torch) and by induction. Gold-machined cylinders were used as controls. Measurement of the vertical misfits of cast cylinders was performed with aid of a light microscope at two periods, before and after utilization of cylinder rectifiers. For the gold machined components, reading was performed only once, since these components were not rectified. The misfit values of the cast cylinders were submitted to statistical analysis by the three-way ANOVA and Tukey tests (5%). Comparisons between the rectified cast cylinders and machined cylinders were performed by the Student t test for non-paired samples. The reduction in misfit was considered significant (p<0.05) for the components cast in Ni-Cr. With regard to the components cast in Co-Cr, the reduction in misfit was not considered significant for all groups of components. The means of marginal misfit for the Micro Unit components cast in Ni-Cr by the conventional technique (torch) after utilization of cylinder rectifiers (29,08mm) were not statistically different (p> 0,05) from the gold machined cylinders means (22,44mm). The utilization of manual rectifiers on cast cylinders led to significant reductions in marginal misfit of components cast in Ni-Cr alloy.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Dental Implants / Chromium Alloys / Osseointegration / Metal Ceramic Alloys / Dental Marginal Adaptation Language: Portuguese Journal: Odonto (Säo Bernardo do Campo) Journal subject: Dentistry Year: 2008 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista/BR / Universidade Federal de Santa Catarina/BR / Universidade Metodista de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Dental Implants / Chromium Alloys / Osseointegration / Metal Ceramic Alloys / Dental Marginal Adaptation Language: Portuguese Journal: Odonto (Säo Bernardo do Campo) Journal subject: Dentistry Year: 2008 Type: Article / Project document Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista/BR / Universidade Federal de Santa Catarina/BR / Universidade Metodista de São Paulo/BR