Your browser doesn't support javascript.
loading
Resultados preliminares del perfeccionamiento del DAVIH-AgP24 con el empleo del sistema de amplificación biotina-tiramina/estreptavidina-peroxidasa / Preliminary results of DAVIH-AgP24 with the biotin-tiramyne/streptavidine-peroxidase amplification system
Fragas Quintero, Anitza; Ortiz Losada, Eva; Díaz Torres, Héctor M; Silva Cabrera, Eladio; Izquierdo Márquez, Maricela.
  • Fragas Quintero, Anitza; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Ortiz Losada, Eva; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Díaz Torres, Héctor M; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Silva Cabrera, Eladio; Laboratorio de Investigaciones del SIDA. La Habana. CU
  • Izquierdo Márquez, Maricela; Laboratorio de Investigaciones del SIDA. La Habana. CU
Rev. cuba. med. trop ; 61(1)ene.-abr. 2009. graf
Article in Spanish | LILACS | ID: lil-547068
RESUMEN
Se modificó el ELISA DAVIH-Ag P24 con la introducción de la disociación por calor de las muestras de plasma y el empleo de un sistema de amplificación biotina-tiramina/estreptavidina-peroxidasa, para incrementar su sensibilidad. Se determinó la repetibilidad interensayo en el DAVIH-Ag P24 amplificado. Se evaluaron 32 muestras de plasma de individuos infectados por el VIH-1 en 3 categorías clínicas (caso SIDA, asintomßticos y con infecciones oportunistas menores). En la determinación de la repetibilidad interensayo se obtuvo un coeficiente de variación entre 4 y 10,3 por ciento. Con el DAVIH-Ag P24 amplificado se incrementó el nivel de detección de P 24 hasta 0,5 pg/mL. El DAVIH-Ag P24 amplificado alcanzó 66 por ciento de sensibilidad, mientras que el DAVIH-Ag P24 obtuvo 31 por ciento. Este estudio preliminar permitió demostrar que la incorporación de las nuevas modificaciones al sistema DAVIH-Ag P24 amplificado logró aumentar los niveles de detección de P24 y ganar en sensibilidad.
ABSTRACT
ELISA DAVIH-Ag p24 was modified by introducing heat dissociation of plasma samples and a tyramine/streptavidine-peroxidase amplification system, with the objective of increasing sensitivity. Between-assay repeatability was determined in amplified DAVIH-Ag p24. Thirty two plasma samples from HIV-1-infected individuals classified in three clinical categories (AIDS case, asymptomatic and minor opportunistic infections) were evaluated. The variation coefficient ranged 4-10.3 percent in between-assay repeatability. With the amplified DAVIH-p24 Ag, the p24 antigen detection level increased to 0.5 pg/mL. Amplified DAVIH-p24 Ag reached 66 percent sensitivity whereas standard DAVIH-p24 Ag sensitivity rate was 31 percent. This preliminary study proved that the introduction of new modifications in amplified DAVIH-p24 Ag managed to increase the p24 antigen detection levels and to gain sensitivity.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: HIV Limits: Humans Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2009 Type: Article Affiliation country: Cuba Institution/Affiliation country: Laboratorio de Investigaciones del SIDA/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: HIV Limits: Humans Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2009 Type: Article Affiliation country: Cuba Institution/Affiliation country: Laboratorio de Investigaciones del SIDA/CU