Efeito da hemodiluição normovolêmica aguda na coagulação sanguínea: comparação entre os testes colhidos de um modelo in vivo e de um modelo in vitro / Efecto de la hemodilución normovolémica aguda en la coagulación sanguínea: comparación entre los tests recolectados en un modelo in vivo y en un modelo in vitro / Effects of acute normovolemic hemodilution on blood coagulation: comparison between tests of an in vivo and an in vitro model
Souza, Marco Aurélio Beloto de; Klamt, Jyrson Guilherme; Garcia, Luís Vicente.
  • Souza, Marco Aurélio Beloto de; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
  • Klamt, Jyrson Guilherme; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Disciplina de Anestesiologia. Ribeirão Preto. BR
  • Garcia, Luís Vicente; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Disciplina de Anestesiologia. Ribeirão Preto. BR
Rev. bras. anestesiol ; 60(4): 363-375, jul.-ago. 2010. graf, tab
Article in English, Portuguese | LILACS | ID: lil-554322
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

A hemodiluição normovolêmica produz resultados conflitantes na hemostasia, pois os trabalhos diferem quanto a tipo de líquido utilizado, profundidade da hemodiluição, método utilizado para avaliar a hemostasia e forma de se produzir hemodiluição. O efeito da hemodiluição na hemostasia pode depender da forma como ela é feita, se no modelo in vivo ou no modelo in vitro. O objetivo deste estudo foi avaliar e comparar a hemostasia em ambos os modelos, em dois diferentes graus de profundidade.

MÉTODO:

Treze pacientes foram submetidos à hemodiluição normovolêmica aguda e o hematócrito foi reduzido para 30 por cento e 20 por cento. A volemia foi mantida com lactato de Ringer. Foram colhidas amostras de sangue para avaliação da hemostasia nos momentos M1 antes da hemodiluição, M2 20 minutos após a obtenção do hematócrito de 30 por cento e M3 20 minutos após a obtenção do hematócrito de 20 por cento. Antes da hemodiluição, amostras de sangue foram colhidas para a realização da hemodiluição em um tubo de ensaio. Os graus de hemodiluição no tubo de ensaio (in vitro) foram os mesmos que os produzidos nos pacientes (in vivo). A hemostasia foi avaliada por meio dos tempos de protrombina, tromboplastina parcial ativado e de trombina e da quantificação do fibrinogênio.

RESULTADOS:

O comportamento dos testes que avaliaram a hemostasia foi idêntico nos dois modelos utilizados. Houve aumento do TP, do TTPA e do TT e diminuição da concentração de fibrinogênio. Quanto maior o grau de hemodiluição, maior o comprometimento da coagulação.

CONCLUSÕES:

O modelo in vitro pode substituir o modelo in vivo na avaliação da hemostasia durante hemodiluição normovolêmica aguda.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Normovolemic hemodilution produces conflicting results on hemostasis, since works differ according to the fluids used, degree of hemodilution, method used to evaluate hemostasis, and the way used to produce hemodilution. The effects of hemodilution on hemostasis can depend on how it is done and whether an in vivo or an in vitro model is used. The objective of this study was to evaluate and compare hemostasis in two different degrees of hemodilution in both models.

METHODS:

Thirteen patients underwent acute normovolemic hemodilution with a reduction in hematocrit to 30 percent and 20 percent. Volemia was maintained with Ringer's lactate. Blood samples for evaluation of hemostasis were collected at moments M1 before hemodilution, M2 20 minutes after obtaining a hematocrit of 30 percent, and M3 20 minutes after obtaining a hematocrit of 20 percent. Before hemodilution, blood samples were collected to perform hemodilution in a test tube. The degree of hemodilution in the test tube (in vitro) was the same as that produced in the patients (in vivo). Hemostasis was evaluated by the prothrombin time, partial activated thromboplastin time, and thrombin time, and by quantifying fibrinogen.

RESULTS:

The behavior of the tests that evaluated hemostasis was identical in both models. An increase in PT, aPTT, and TT, as well as a reduction in the concentration of fibrinogen was observed. The higher degree of hemodilution was associated with greater compromise of coagulation.

CONCLUSIONS:

The in vitro model can substitute the in vivo mode in the evaluation of hemostasis during acute normovolemic hemodilution.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

La Hemodilución normovolémica produce resultados conflictivos en la hemostasia, porque los trabajos se diferencian en cuanto al tipo de líquido utilizado, profundidad de la hemodilución, método utilizado para evaluar la hemostasia y forma de producir la hemodilución. El efecto de la hemodilución en la hemostasia puede depender de la forma como ella se realiza, si es en el modelo in vivo o en el modelo in vitro. El objetivo de este estudio fue evaluar y comparar la hemostasia en los dos modelos, en dos diferentes grados de profundidad.

MÉTODO:

Trece pacientes se sometieron a la hemodilución normovolémica aguda y el hematocrito fue reducido para 30 por ciento y 20 por ciento. La volemia se mantuvo con Ringer con lactato. Se recogieron muestras de sangre para evaluación de la hemostasia en los momentos M1 (antes de la Hemodilución, M2 20 minutos después de la obtención del hematocrito de 30 por ciento) y M3 (20 minutos después de la obtención del hematocrito de 20 por ciento). Antes de la Hemodilución, muestras de sangre se recogieron para la realización de la Hemodilución en un tubo de ensayo. Los grados de Hemodilución en el tubo de ensayo (in vitro) fueron los mismos que los producidos en los pacientes (in vivo). La hemostasia fue evaluada por medio de los tiempos de protrombina, tromboplastina parcial activado, trombina y de la cuantificación del fibrinógeno.

RESULTADOS:

El comportamiento de los tests que evaluaron la hemostasia fue idéntico en los dos modelos utilizados. Hubo un aumento del TP, del TTPA y del TT y una reducción de la concentración de fibrinógeno. Mientras mayor el grado de hemodilución, mayor el comprometimiento de la coagulación.

CONCLUSIONES:

El modelo in vitro puede reemplazar al modelo in vivo en la evaluación de la hemostasia durante la hemodilución normovolémica aguda.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Blood Coagulation / Hemodilution Limits: Adolescent / Adult / Female / Humans / Male Language: English / Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Blood Coagulation / Hemodilution Limits: Adolescent / Adult / Female / Humans / Male Language: English / Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR