RESUMEN

Introducción:

El uso irresponsable de reproductores de música personal ha sido considerado como una conducta de riesgo en salud emergente.

Objetivos:

Determinar el perfil sonorométrico de distintos tipos de reproductores, con distintos tipos de fonos y a distintos niveles de control de volumen, estimando niveles de trauma acústico mediante normas para trauma acústico ocupacional. Material y

método:

Estudio descriptivo. Con sonómetro en cámara silente y utilizando muestra estandarizada de música se evaluaron 3 tipos de reproductor y 2 tipos de fonos a 25 por ciento, 50 por ciento, 75 por ciento y 100 por ciento del nivel máximo de salida.

Resultados:

El nivel de salida alcanzó un máximo de 119 dB SPL(A). Existen diferencias entre tipos de reproductor. Fonos supraauriculares reducen de manera constante alrededor de 12 dB el nivel de salida, independientemente del aparato o nivel de volumen utilizado. Bajo 50 por ciento del volumen máximo ningún tipo de reproductor alcanza una dosis de ruido (equivalente a 85dB en 8 horas) en menos de 24 horas. A 75 por ciento de volumen se alcanza una dosis de ruido hasta en 1,9 horas, pero a 100 por ciento se alcanza hasta en 4,5 minutos. Discusiones Los reproductores de música personal pueden emitir altas presiones sonoras consideradas riesgosas según normas para trauma acústico ocupacional. Aparentemente el uso de audífonos supraauriculares pudiese ser beneficioso, aunque finalmente el daño acústico potencial depende del nivel de intensidad escogido por el usuario, y el tiempo de uso. Esperamos que este trabajo contribuya a tomar conciencia sobre esta nueva conducta de riesgo en salud auditiva.
ABSTRACT

Introduction:

An irresponsible use of personal music players has been considered as an emerging health risk behavior.

Aim:

To determine output profiles of different personal music players, considering different phone types and different volume/output control levels, thus estimating exposure limits by noise-induced hearing loss guidelines. Material and

methods:

Descriptive study. We evaluated sound pressure outputs within an audiometric silent chamber using a standardized music sample in 3 types of players and 2 types of phones at 25 percent, 50 percent, 75 percent and 100 percent of maximum output.

Results:

The peak output pressure was 119 dB SPL (A). There were significant differences between players. Supra-ear phones steadily reduced about 12 dB of output pressure, regardless of the device or volume level selected. Under 50 percent of maximum output no player reached one noise-dose (equivalent to 85 dB at 8 hours, maximum noise exposure permitted in many guidelines) within 24 hrs. At 75 percent of maximum output one noise-dose was reached up to 1.9 hours. At 100 percent of output it was achieved as short as in 4.5 minutes. Discussions Personal music players can emit high sound pressures considered risky by noise-induced hearing loss standards. Apparently the use of supra-ear headphones could be beneficial, but ultimately the potential acoustic damage depends on the intensity/output level chosen by the user and the usage time. We hope this work will help raise awareness about this emerging health risk behavior.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Risk-Taking / Hearing Loss, Noise-Induced Type of study: Etiology study / Qualitative research / Risk factors Limits: Humans Language: Spanish Journal: Rev. otorrinolaringol. cir. cabeza cuello Journal subject: Otolaryngology Year: 2009 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Risk-Taking / Hearing Loss, Noise-Induced Type of study: Etiology study / Qualitative research / Risk factors Limits: Humans Language: Spanish Journal: Rev. otorrinolaringol. cir. cabeza cuello Journal subject: Otolaryngology Year: 2009 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL