Your browser doesn't support javascript.
loading
Desenvolvimento e validação de método analítico para quantificação de diclofenaco de dietilamônio em pele humana por cromatografia líquida de alta eficiência / Development and validation of an analytical method for quantitation of diclofenac diethylamine in human skin by high performance liquid chromatography
Silva, J. A; Bedor, D. C. G; Sousa, C. E. M; Santana, D. P; Egito, E. S. T.
  • Silva, J. A; Universidade Estadual da Paraíba. Departamento de Farmácia. Campina Grande. BR
  • Bedor, D. C. G; Universidade Federal de Pernambuco. Centro de Ciências da Saúde. Departamento de Ciências Farmacêuticas. BR
  • Sousa, C. E. M; Universidade Federal de Pernambuco. Centro de Ciências da Saúde. Departamento de Ciências Farmacêuticas. BR
  • Santana, D. P; Universidade Federal de Pernambuco. Centro de Ciências da Saúde. Departamento de Ciências Farmacêuticas. BR
  • Egito, E. S. T; Universidade Federal do Rio Grande do Norte. Laboratório de Sistemas Dispersos. Departamento de Farmácia. BR
Article in Portuguese | LILACS | ID: lil-560253
RESUMO
Foi desenvolvido e validado neste estudo um método analítico para quantificação de diclofenaco de dietilamônio em pele humana por cromatografia líquida de alta eficiência, segundo a Resolução 899/2003 da Agência Nacional de Vigilância Sanitária (ANVISA). Empregou-se cromatografia em fase reversa com coluna C18 150 x 4,6 mm, 5 µm Shimpack®, à temperatura de 40ºC e fase móvel, constituída por mistura de acetonitrila e tampão fosfato de sódio 20 mM pH 3,0 (7030, v/v) com fluxo de 1,2 mL min-1. Os analitos foram detectados por UV a 280 nm e o método foi especifico, preciso, exato, robusto e linear no intervalo de 0,05 a 20 µg mL-1 (R2 = 0,998), mostrando que pode ser utilizado em estudos de penetração cutânea in vitro tendo como modelo de membrana a pele humana.
ABSTRACT
An analytical method has been developed and validated for the quantitation of diclofenac diethylamine (DDA) in human skin by high performance liquid chromatography (HPLC), in accordance with Regulation 899/2003 of the National Sanitary Surveillance Agency (ANVISA). The HPLC column was a reversed-phase Shimpack® C18, with a 5 µm particle bed, measuring 150 x 4.6 mm i.d., eluted isocratically at 40ºC with 20 mM sodium phosphate buffer (pH 3.0)acetonitrile (3070, v/v), the mobile phase flowing at 1.2 mL min-1. Analytes were measured by a UV detector set at 280 nm. The results revealed that the method was specific, precise, accurate, robust and linear (R2=0.998) in the range from 0.05 to 20 µg mL-1. Therefore, it can safely be used to assess DDA in vitro penetration of human skin in kinetic studies.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Skin Absorption / Diclofenac Limits: Humans Language: Portuguese Journal: Rev. ciênc. farm. básica apl Journal subject: Pharmacology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual da Paraíba/BR / Universidade Federal de Pernambuco/BR / Universidade Federal do Rio Grande do Norte/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Skin Absorption / Diclofenac Limits: Humans Language: Portuguese Journal: Rev. ciênc. farm. básica apl Journal subject: Pharmacology Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual da Paraíba/BR / Universidade Federal de Pernambuco/BR / Universidade Federal do Rio Grande do Norte/BR