Concordancia de las técnicas subjetivas que miden la amplitud de acomodación / Concordance between subjective techniques that measure amplitude of accommodation
Cienc. tecnol. salud vis. ocul
;
8(1)ene. 2010.
Article
in Spanish
| LILACS
| ID: lil-560865
RESUMEN
Objetivo: determinar la repetitividad inter observador y la concordancia entre las pruebas clínicas que miden la amplitud de acomodación (AA). Metodología: fueron evaluados setenta y nueve sujetos entre los 18 a 30 años, que presentaban un estado visual refractivo y acomodativo normales. Las pruebas clínicas realizadas fueron la técnica de Sheard (lente negativo de cerca) Jackson (lente negativo de lejos) y Donders modificada (alejamiento más un lente de -4.00D). Resultados: el Coeficiente de Correlación Intraclase (ICC) mostró que las pruebas demostraban una alta repetitividad (>0,7); el Coeficiente de Correlación y Concordanciade Lin (pc) reveló una pobre repetitividad y concordancia entre las pruebas (pc<0,9). Los límites de acuerdo para Donders, Sheard y Jackson (+/-1,22; +/-2,02, +/-3,44) revelan una menor variación de la AA entre los observadores para Donders y mayor paraJackson. Conclusión: la repetitividad inter observadora es mayor para la técnica de Donders modificada y la concordancia entre las pruebas es pobre, por lo que no son intercambiables.
ABSTRACT
The purpose was determinate reliability test retestand concordance between clinical techniques that measure amplitude of accommodation. Methods: seventy nine students who had normal visual function, refractive and accommodative skills participated.The techniques were: minus lens (near), minus lens (far) and push down modified (-4.00D lens). Results: Intraclass Correlation Coefficient (ICC) show that test retest was high three techniques(>0,7); Concordance correlation coefficient of Lin (pc) showed that agreement was poor for all of them(pc<0,9). Limits of agreement (95 percent) were push down modified +/-1,22; minus lens near +/-2,02; minus lens far +/- 3,44. Conclusion: reliability test retest was higher for push down modified and concordance between the techniques was poor so, these are not interchangeable.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Refraction, Ocular
/
Diagnostic Techniques, Ophthalmological
/
Accommodation, Ocular
Limits:
Adult
Language:
Spanish
Journal:
Cienc. tecnol. salud vis. ocul
Journal subject:
Medical Informatics
/
Ophthalmology
/
Optometry
/
TECNOLOGIA
Year:
2010
Type:
Article
Affiliation country:
Colombia
Institution/Affiliation country:
Fundación Universitaria del Área Andina seccional Pereira/CO
Similar
MEDLINE
...
LILACS
LIS