Your browser doesn't support javascript.
loading
Análise do movimento de abdução do ombro pelo sistema óptico / Analysis of the movement the abduction of the shoulder by the optic system
Sônego, Denise Aparecida; Cliquet Júnior, Alberto.
  • Sônego, Denise Aparecida; Universidade Estadual de Campinas. Faculdade de Medicina. Departamento de Ortopedia e Traumatologia. Laboratório de Biomecânica e Reabilitação do Aparelho Locomotor. Campinas. BR
  • Cliquet Júnior, Alberto; Universidade de São Paulo. Departamento de Engenharia Elétrica. São Paulo. BR
Biosci. j ; 22(2): 147-158, May-Aug. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-561912
RESUMO
Sistemas ópticos de captura dos movimentos são recursos poderosos de medição para analisar o movimento articular. A proposta deste estudo foi verificar a aplicação do sistema óptico Qualisys na análise do movimento de abdução do ombro, para isso foram comparados indivíduos com amplitude de movimento normal da articulação do ombro, com indivíduos que apresentaram dificuldade na realização e diminuição no movimento articular.Dezessete indivíduos saudáveis foram avaliados. A análise do movimento foi instituída, utilizando o rograma “QView”e os dados exportados para o programa “Qtools 2.0” Três câmeras de vídeo com amostragem de 60 Hz foramutilizadas. Marcadores reflexíveis foram colocados em estruturas anatômicas, para a obtenção das coordenadastridimensionais. Para fins estatísticos, foi utilizado o teste de Mann-Whitney, gráfico de ponto e teste T para umaamostra, demonstrando as diferenças nos movimentos e amplitudes articulares entre ombros patológicos e normais.
ABSTRACT
Optical systems of motion capture are powerful resources of measurement to analyse the articular movement. The purpose of this study was to verify the application of the Qualiys´s optical system towardscomparing pathological individuals with amplitude of normal movement of the shoulder joint, with individuals whohad reduction in the movement to articulate. Seventeen healthy individuals were evaluated. The movement analysiswas done using “Qviews” software, the data exported to “Qtools 2.0” software. Three video cameras at 60 Hz sampling frequency were used. Reflexive marks were placed in anatomical structures, to obtain the three-dimensional coordinates Mann-Whitney test was used to verify the application of the Qualiys's optical system, demonstrating the differences in the movement and joint amplitudes both in pathological and normal shoulders.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Shoulder / Shoulder Joint / Movement Limits: Female / Humans / Male Language: Portuguese Journal: Biosci. j Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR / Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Shoulder / Shoulder Joint / Movement Limits: Female / Humans / Male Language: Portuguese Journal: Biosci. j Year: 2006 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual de Campinas/BR / Universidade de São Paulo/BR