Your browser doesn't support javascript.
loading
Implante transapical de valva aórtica: resultados de uma nova prótese brasileira / Transapical aortic valve implantation: results of a brazilian prosthesis
Gaia, Diego Felipe; Palma, José Honório; Ferreira, Carolina Baeta Neves Duarte; Souza, José Augusto Marcondes de; Agreli, Guilherme; Guilhen, José Cícero Stocco; Telis, André; Buffolo, Enio.
  • Gaia, Diego Felipe; s.af
  • Palma, José Honório; s.af
  • Ferreira, Carolina Baeta Neves Duarte; s.af
  • Souza, José Augusto Marcondes de; s.af
  • Agreli, Guilherme; s.af
  • Guilhen, José Cícero Stocco; s.af
  • Telis, André; s.af
  • Buffolo, Enio; s.af
Rev. bras. cir. cardiovasc ; 25(3): 293-302, jul.-set. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-564994
RESUMO

OBJETIVO:

A troca valvar aórtica é procedimento rotineiro com risco aceitável. Em alguns casos, a mortalidade é elevada, levando à contraindicação do procedimento, apesar dos sintomas. O implante minimamente invasivo transcateter de valva aórtica parece ser uma alternativa, reduzindo a morbi-mortalidade. O objetivo deste estudo foi o desenvolvimento e implante de nova prótese para implante transcateter.

MÉTODOS:

Após desenvolvimento em animais, uma prótese transcateter, balão-expansível foi utilizada em 14 casos de alto risco. O EuroSCORE médio foi de 43,7 por cento. Quatro pacientes apresentavam disfunção de biopróteses e o restante, estenose aórtica calcificada. Todos os pacientes eram sintomáticos. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Com o uso de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência ou choque hemorrágico controlado, após valvoplastia aórtica. Foram realizados controles clínicos e ecocardiográficos seriados.

RESULTADOS:

A correta liberação da prótese foi possível em 13 casos. Uma conversão ocorreu. Não houve mortalidade operatória. O gradiente de pico médio pós-implante foi de 25 mmHg. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório. Insuficiência aórtica residual não significativa esteve presente em 71 por cento dos casos, nenhuma significativa. Não ocorreu complicação vascular periférica. Não houve necessidade de marcapasso definitivo. Um caso de acidente vascular cerebral ocorreu. A mortalidade geral foi de 42 por cento.

CONCLUSÃO:

O implante transapical de valva aórtica transcateter é um procedimento possível com esta nova prótese. O comportamento hemodinâmico foi satisfatório. São necessários estudos de longo prazo e com maior poder amostral, no intuito de determinar a real eficácia e indicação do procedimento alternativo.
ABSTRACT

OBJECTIVE:

The aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such a risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for the aortic position implant.

METHODS:

After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median Logistic EuroSCORE was 43.7 percent. Four patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. All patients presented symptoms. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis was implanted through the ventricular apex under ventricular pacing or hemorrhagic shock, after aortic valvoplasty. Echocardiograph and angiograph controls were performed, and the patients were referred to ICU.

RESULTS:

Implant was feasible in 13 cases. There were no intra-operative deaths. Median peak transvalvular aortic gradient reduced to 25.0 mmHg, and left ventricular function improved in the first seven post-operative days. Paravalvular aortic regurgitation was mild and present in 71 percent. No definitive pacemaker was needed. There was no peripheral vascular complication. Overall mortality was 42 percent.

CONCLUSION:

The transapical implantation of cathetermounted bioprosthesis was a feasible procedure. Long term follow-up is mandatory in order to access efficacy and indications.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Aortic Valve Stenosis / Thoracotomy / Heart Valve Prosthesis Implantation Type of study: Evaluation studies / Practice guideline Limits: Adult / Aged / Aged80 / Female / Humans / Male Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Aortic Valve Stenosis / Thoracotomy / Heart Valve Prosthesis Implantation Type of study: Evaluation studies / Practice guideline Limits: Adult / Aged / Aged80 / Female / Humans / Male Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2010 Type: Article