Your browser doesn't support javascript.
loading
Emprego experimental da placa de compósito poli-hidroxibutirado/hidroxiapatita na fixação femoral em gatos / Experimental employment of polyhydroxybutyrate/hydroxyapatite composite plates in femoral fixation in cats
Alves, E. G. L; Rezende, C. M. F; Oliveira, H. P; Borges, N. F; Mantovani, P. F; Rosado, I. R.
  • Alves, E. G. L; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Rezende, C. M. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Oliveira, H. P; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Borges, N. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Mantovani, P. F; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
  • Rosado, I. R; Universidade Federal de Minas Gerais. Escola de Veterinária. BR
Arq. bras. med. vet. zootec ; 62(5): 1128-1134, out. 2010. ilus
Article in Portuguese | LILACS | ID: lil-570471
RESUMO
Avaliou-se o compósito de poli-hidroxibutirado (PHB) 70 por cento e hidroxiapatita (HA) 30 por cento na forma de placas para fixação óssea em gatos. Foram usadas placas do compósito com 60mm de comprimento por 10mm de largura e espessura variando de 3mm no centro a 5mm nas extremidades, com seis orifícios. A placa do compósito foi empregada na fixação de osteotomia de fêmur em quatro gatos, totalizando seis intervenções. Verificou-se a ruptura de cinco placas (83,3 por cento) até o quarto dia e de uma placa (16,7 por cento) aos 21 dias, quando se observou um calo ósseo exuberante. O resultado da implantação da placa no gato mostrou que o compósito não possui resistência suficiente para ser empregado como placas de fixação de fêmur em gatos.
ABSTRACT
The composite of polyhydroxybutyrate (PHB) 70 percent and hydroxyapatite (HA) 30 percent was evaluated as plate for bone fixation in cats. The employed composite plates presented six orifices and measured 60 x 10mm, length and width, respectively, with thickness ranging from 3 to 5mm according to the region. The composite plate was used in the fixation of femoral osteotomy in four cats, in a total of six interventions. There were ruptures in five plates (83.3 percent) until day 4 and in one plate (16.7 percent) on the day 21, when it was possible to observe an exuberant osseous callus. The result of the plate deployment in the cat showed that the composite does not have sufficient strength to be used as plate of femoral fixation in cats.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Biocompatible Materials / Fracture Fixation Limits: Animals Language: Portuguese Journal: Arq. bras. med. vet. zootec Journal subject: Veterinary Medicine Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Biocompatible Materials / Fracture Fixation Limits: Animals Language: Portuguese Journal: Arq. bras. med. vet. zootec Journal subject: Veterinary Medicine Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR