Your browser doesn't support javascript.
loading
Anel corneano intraestromal assimétrico no tratamento do ceratocone / Asymmetric intrastromal corneal ring for the treatment of keratoconus
Siqueira, Marcelo Alves Vilar de; Polo, Jhonny de; Gomes, Manuela Benites; Moreira, Hamilton.
  • Siqueira, Marcelo Alves Vilar de; s.af
  • Polo, Jhonny de; s.af
  • Gomes, Manuela Benites; s.af
  • Moreira, Hamilton; s.af
Arq. bras. oftalmol ; 73(5): 454-458, Sept.-Oct. 2010. graf, tab
Article in Portuguese | LILACS | ID: lil-570509
RESUMO

OBJETIVOS:

Analisar as alterações na curvatura corneana e acuidade visual após o implante de anéis intraestromais assimétricos, modificando o nomograma proposto pelo fabricante.

MÉTODOS:

Foram estudados sete olhos, de sete pacientes portadores de ceratocone nos quais foram implantados segmentos de anéis assimétricos (350 a 100 micra de espessura).

RESULTADOS:

Constatou-se através do estudo que em todos os pacientes houve um aplanamento da ceratometria corneana média com aumento da assimetria corneana no pós-operatório.

CONCLUSÕES:

O implante de anel corneano intraestromal assimé­trico leva à melhora da acuidade visual pós-operatória tanto sem correção quanto com correção. Resulta no aplanamento da curvatura corneana nos pontos estudados, obtendo assim, diminuição das distorções centrais pelo aplanamento topográfico da região central da córnea.
ABSTRACT

PURPOSE:

To analyze corneal curvature and visual acuity after asymmetric intrastromal corneal rings implantation, not following the nomogram proposed by the manufacturer.

METHODS:

Seven eyes of seven keratoconus patients which had asymmetric corneal rings implanted in their corneal stroma were studied.

RESULTS:

A flattening of the average corneal keratometry was noted in all patients, as well as an increase of the postoperative corneal asymmetry.

CONCLUSIONS:

Asymmetric intrastromal corneal ring implant improves the postoperative visual acuity with and without correction. As a result we noticed flattening of the corneal curvature at the thicker ring implantation spot and increase of corneal asymmetry.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Visual Acuity / Corneal Stroma / Prosthesis Implantation / Keratoconus Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Visual Acuity / Corneal Stroma / Prosthesis Implantation / Keratoconus Limits: Adult / Female / Humans / Male Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article