Your browser doesn't support javascript.
loading
Injeção intraoperatória de dextran-500-99m_tecnécio para identificação do linfonodo sentinela em câncer de mama / Intraoperative injection of technetium-99m-dextran 500 for the identification of sentinel lymph node in breast cancer
Delazeri, Gerson Jacob; Xavier, Nilton Leite; Menke, Carlos Henrique; Bittelbrunn, Ana Cristina; Spiro, Bernardo Leão; Mosmann, Marcos Pretto; Graudenz, Márcia Silveira.
  • Delazeri, Gerson Jacob; Universidade Federal do Rio Grande do Sul. Programa de Pós-Graduação em Medicina - Ciências Médicas. Porto Alegre. BR
  • Xavier, Nilton Leite; Universidade Federal do Rio Grande do Sul. Departamento de Ginecologia e Obstetrícia. Porto Alegra. BR
  • Menke, Carlos Henrique; Universidade Federal do Rio Grande do Sul. Departamento de Ginecologia e Obstetrícia. Porto Alegra. BR
  • Bittelbrunn, Ana Cristina; Hospital de Clínicas de Porto Alegre. Serviço de Mastologia. Porto Alegre. BR
  • Spiro, Bernardo Leão; Universidade Federal do Rio Grande do Sul. Faculdade de Medicina. Departamento de Radiologia. Porto Alegre. BR
  • Mosmann, Marcos Pretto; Hospital de Clínicas de Porto Alegre. Serviço de Medicina Nuclear. Porto Alegre. BR
  • Graudenz, Márcia Silveira; Universidade Federal do Rio Grande do Sul. Programa de Pós-Graduação em Medicina - Ciências Médicas. Porto Alegre. BR
Rev. bras. ginecol. obstet ; 32(10): 486-490, out. 2010. tab
Article in Portuguese | LILACS | ID: lil-572629
RESUMO

OBJETIVO:

avaliar a eficácia da injeção intraoperatória para identificação do LS em câncer de mama com o uso do Dextran 500-99m-tecnécio (Tc) e analisar o tempo para marcação do linfonodo sentinela (LS) axilar.

MÉTODOS:

estudo prospectivo realizado entre abril de 2008 e junho de 2009 que incluiu 74 biópsias de LS em pacientes com câncer de mama em estádios T1N0 e T2N0. Após a indução anestésica, injetou-se de 0,5 a 1,5 mCi (18 a 55 MBq) de Dextran 500-99m-Tc filtrado 0,22 µm num volume de 5 mL de acordo com a técnica de injeção subareolar para a biópsia do LS. Após a marcação com o radiofármaco injetou-se 2 mL de azul patente. O tempo entre a injeção e a marcação na região axilar, a contagem com o probe do LS in vivo, ex vivo, background e o número de LS identificados foram documentados. Os dados foram analisados por meio da estatística descritiva pelo programa SPSS, versão 18.

RESULTADOS:

identificamos o LS em 100 por cento dos casos. A taxa de identificação com o probe foi de 98 por cento (73/74 casos). Um caso (1,35 por cento) estava marcado apenas com o azul. A dose média do radiofármaco aplicada foi 0,97 mCi±0,22. O tempo para marcação na região axilar, após a injeção subareolar, foi de 10,7 minutos (±5,7 min. ). Foram identificados, em média, 1,66 linfonodos marcados com o radioisotopo.

CONCLUSÃO:

o procedimento para identificação do LS com injeção intraoperatória do radiofármaco é oncologicamente seguro, apresentando conforto ao paciente e agilidade à equipe cirúrgica.
ABSTRACT

PURPOSE:

to determine the efficacy of intraoperative injection of Dextran-500-99m-technetium (Tc) for the identification of the sentinel lymph node (SLN) in breast cancer and analyze time to label the SLN in the axillary region.

METHODS:

a prospective study between April 2008 and June 2009, which included 74 sentinel lymph node biopsies (SLNB) in patients with breast cancer in stages T1N0 and T2N0. After induction of anesthesia, 0.5 to 1.5 mCi of Dextran-500-99m-Tc filtered 0.22 µm in a volume of 5 mL was injected intraoperative using the subareolar technique for SLNB. After labeling with the radioisotope, 2 mL of patent blue was injected. The time elapsed between injection and the axillary hot spot, the in vivo and ex vivo counts of the hottest nodes, the background count, and the number of SLN identified were documented. Data were analyzed using descriptive statistics with SPSS program, version 18.

RESULTS:

we identified the SLN in 100 percent of cases. The rate of SLN identification with the probe was 98 percent (73/74 cases). In one case (1.35 percent) the SLN was labeled only with the blue dye. The mean dose of radioisotope injected was 0.97±0.22 mCi. The average time to label the SLN was 10.7 minutes (±5.7 min). We identified on average of 1.66 SLN labeled with the radioisotope.

CONCLUSION:

the procedure for SLN identification with an intraoperative injection of the radioisotope is oncologically safe and comfortable for the patient, providing agility to the surgical team.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Breast Neoplasms / Organotechnetium Compounds / Dextrans / Radiopharmaceuticals / Sentinel Lymph Node Biopsy / Intraoperative Care Type of study: Diagnostic study / Observational study Limits: Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Breast Neoplasms / Organotechnetium Compounds / Dextrans / Radiopharmaceuticals / Sentinel Lymph Node Biopsy / Intraoperative Care Type of study: Diagnostic study / Observational study Limits: Female / Humans Language: Portuguese Journal: Rev. bras. ginecol. obstet Journal subject: Gynecology / Obstetrics Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR