Disfunção do homoenxerto pulmonar utilizado na reconstrução do trato de saída do ventrículo direito / Dysfunction of the pulmonary homograft used in the reconstruction of the right ventricle exit tract / Disfunción del homoinjerto pulmonar utilizado en la reconstrucción del tracto de salida del ventrículo derecho
Lenzi, Andréa Weirich; Olandoski, Márcia; Ferreira, Wanderley Saviolo; Sallum, Fabio Said; Miyague, Nelson Itiro.
  • Lenzi, Andréa Weirich; Pontificia Universidade Católica Paraná. Hospital Pequeno Príncipe. Curitiba. BR
  • Olandoski, Márcia; Pontificia Universidade Católica Paraná. Hospital Pequeno Príncipe. Curitiba. BR
  • Ferreira, Wanderley Saviolo; Pontificia Universidade Católica Paraná. Hospital Pequeno Príncipe. Curitiba. BR
  • Sallum, Fabio Said; Pontificia Universidade Católica Paraná. Hospital Pequeno Príncipe. Curitiba. BR
  • Miyague, Nelson Itiro; Pontificia Universidade Católica Paraná. Hospital Pequeno Príncipe. Curitiba. BR
Arq. bras. cardiol ; 96(1): 2-7, jan. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-573601
RESUMO
FUNDAMENTO O homoenxerto pulmonar tem sido utilizado como uma opção na correção de cardiopatia congênita com obstrução da via de saída do ventrículo direito. Os resultados em longo prazo, no entanto, mostram-se pouco satisfatórios.

OBJETIVO:

Identificar os fatores de risco associados à disfunção e à falência do homoenxerto pulmonar.

MÉTODOS:

Estudo em crianças submetidas à ampliação da via de saída do ventrículo direito com homoenxerto pulmonar. As variáveis clínicas, cirúrgicas, evolutivas e de aspectos morfológicos da prótese foram analisadas como fatores de risco.

RESULTADOS:

A amostra final de 75 pacientes com idade mediana na cirurgia de 22 meses, variando de 1-157 meses, apresentou 13 pacientes (17,0 por cento) que desenvolveram disfunção do homoenxerto, caracterizado por estenose ou insuficiência pulmonar grave. O tempo de ocorrência entre o implante do homoenxerto e a detecção da disfunção foi de 45 ± 20 meses. Quando o tamanho do homoenxerto foi menor de 21 mm e o escore Z da valva pulmonar foi menor do que zero, ou maior do que três, foram considerados fatores de risco para a ocorrência de disfunção.

CONCLUSÃO:

O homoenxerto pulmonar de tamanho menor do que 21 mm e a valva pulmonar inadequada para idade e peso do paciente são fatores determinantes para disfunção da prótese.
ABSTRACT

BACKGROUND:

The pulmonary homograft has been used as an option in the correction of congenital cardiopathy with obstruction of the right ventricle exit tract. The long term results, however, are little satisfactory.

OBJECTIVE:

Identify the risk factors associated to the dysfunction and the pulmonary homograft failure.

METHODS:

Study with children submitted to the enlargement of the exit tract of the right ventricle with pulmonary homograft. The clinical, surgical, evolutional and morphological aspects of the prosthesis variables were analyzed as risk factors.

RESULTS:

The final sample of 75 patients with median age at the surgery of 22 months, varying from 1-157 months, presented 13 patients (17.0 percent) who developed dysfunction of the homograft, characterized by stenosis or severe pulmonary insufficiency. The occurrence time between the homograft implant and the detection of the dysfunction was of 45 ± 20 months. When the size of the homograft was smaller than 21 mm and the Z score of the pulmonary valva is lower than zero, or higher than three, the risk factors were considered for the dysfunction occurrence.

CONCLUSION:

The pulmonary homograft smaller than 21 mm and the inadequate pulmonary valva for the age and weight of the patient are determining factors for the prosthesis dysfunction.
RESUMEN
FUNDAMENTO El homoinjerto pulmonar ha sido utilizado como una opción en la corrección de cardiopatía congénita con obstrucción de la vía de salida del ventrículo derecho. Los resultados a largo plazo, mientras tanto, se muestran poco satisfactorios.

OBJETIVO:

Identificar los factores de riesgo asociados a la disfunción y a la falla del homoinjerto pulmonar.

MÉTODOS:

Estudio en niños sometidos a la ampliación de la vía de salida del ventrículo derecho con homoinjerto pulmonar. Las variables clínicas, quirúrgicas, evolutivas y de aspectos morfológicos de la prótesis fueron analizadas como factores de riesgo.

RESULTADOS:

La muestra final de 75 pacientes con edad mediana en la cirugía de 22 meses, variando de 1-157 meses, presentó 13 pacientes (17,0 por ciento) que desarrollaron disfunción del homoinjerto, caracterizado por estenosis o insuficiencia pulmonar grave. El tiempo de ocurrencia entre el implante del homoinjerto y la detección de la disfunción fue de 45 ± 20 meses. Cuando el tamaño del homoinjerto fue menor de 21 mm y el escore Z de la válvula pulmonar fue menor que cero, o mayor que tres, fueron considerados factores de riesgo para la ocurrencia de disfunción.

CONCLUSIÓN:

El homoinjerto pulmonar de tamaño menor que 21 mm y la válvula pulmonar inadecuada para edad y peso del paciente son factores determinantes para disfunción de la prótesis.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Aortic Valve / Pulmonary Valve / Prosthesis Failure / Heart Valve Prosthesis / Ventricular Outflow Obstruction / Heart Ventricles Type of study: Etiology study / Prognostic study / Risk factors Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Infant, Newborn Language: Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontificia Universidade Católica Paraná/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Aortic Valve / Pulmonary Valve / Prosthesis Failure / Heart Valve Prosthesis / Ventricular Outflow Obstruction / Heart Ventricles Type of study: Etiology study / Prognostic study / Risk factors Limits: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Infant, Newborn Language: Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontificia Universidade Católica Paraná/BR