Your browser doesn't support javascript.
loading
Coeficiente de ultrafiltración en dializadores de bajo y alto flujo reusados / Coefficient of ultrafiltration in reused low and high flow dialyzers
Barrios Camba, Joachín; Magrans Buch, Charles; Martínez Soto, Orquídea; Borrego Piñero, Julio.
  • Barrios Camba, Joachín; Instituto de Nefrología Doutor Abelardo Buch López. La Habana. CU
  • Magrans Buch, Charles; Instituto de Nefrología Doutor Abelardo Buch López. La Habana. CU
  • Martínez Soto, Orquídea; Instituto de Nefrología Doutor Abelardo Buch López. La Habana. CU
  • Borrego Piñero, Julio; Instituto de Nefrología Doutor Abelardo Buch López. La Habana. CU
Rev. cuba. med ; 48(1)ene.-mar. 2009. graf
Article in Spanish | LILACS | ID: lil-576639
RESUMEN
El reúso de los dializadores constituye un problema de gran magnitud en nuestro país. Se realizó un estudio observacional, descriptivo, prospectivo para determinar el Kuf de los dializadores de BF y AF reusados. Se estudiaron 8 pacientes en el Servicio de Hemodiálisis del Instituto de Nefrología Dr Abelardo Buch López, durante 18 sem, se utilizaron membranas de BF y AF, durante 2 etapas. El reúso fue automatizado, utilizando como germicida ácido peracético. Se midió Kuf in vitro e in vivo durante todas las hemodiálisis, se realizaron 432 hemodiálisis. El Kuf in vitro e in vivo de ambos tipos de dializadores disminuyó considerablemente en los primeros 6 usos. El Kuf de ambos tipos de dializadores tiene una importante disminución con el reprocesamiento.
ABSTRACT
Reuse of dialyzers is a serious problem in our country. To perform an observational, descriptive and prospective study to determine the Kuf of reused low-flow (LF) and high-flow (HF) dialyzers. Eight patients were studied in Hemodialysis Service of Dr Abelardo Buch López Nephrology Institute during 18 weeks, using LF and HL membranes in two stages. Reuse was automated using peracetic. acid like germicide. In vitro and in vivo Kuf was measured during all Hemodialysis (431 in total). In vitro and in vivo Kuf of both types of dialyzers decrease significantly during the first six uses. Kuf of both types of dialyzers has an important diminution with re-processing.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Ultrafiltration / Renal Dialysis / Hemofiltration / Equipment Reuse Type of study: Observational study Limits: Humans Language: Spanish Journal: Rev. cuba. med Journal subject: Medicine Year: 2009 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto de Nefrología Doutor Abelardo Buch López/CU

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Ultrafiltration / Renal Dialysis / Hemofiltration / Equipment Reuse Type of study: Observational study Limits: Humans Language: Spanish Journal: Rev. cuba. med Journal subject: Medicine Year: 2009 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto de Nefrología Doutor Abelardo Buch López/CU