Correlação entre a avaliação microscópica e a leitura por laser fluorescência de lesões de manchas brancas em dentes bovinos: estudo in vitro / Correlation between the microscopic evaluation and reading by laser fluorescence of enamel decalcification in bovine teeth: in vitro study
Odonto (Säo Bernardo do Campo)
;
18(36): 31-39, jul.-dez. 2010. ilus, tab, graf
Article
in Portuguese
| LILACS, BBO
| ID: lil-578097
RESUMO
Objetivo:
avaliar a correlação entre as leituras de descalcificação artificial de esmalte in vitro por meio do DIAGNOdent® e pela microscopia óptica com luz polarizada.Metodologia:
foram utilizados 25 dentes bovinos que foram expostos a um meio artificial de cáries por uma hora, duas vezes ao dia, por 35 dias. Em seguida, procedeu-se as leituras das fluorescências utilizando o aparelho laser DIAGNOdent®. Foram registradas as leituras das áreas sem descalcificação (para calibração) e as áreas desmineralizadas artificialmente. Após as leituras da fluorescência, as regiões de leitura por laser foram cortadas em secções de aproximadamente 400μm e avaliadas por meio da microscopia de luz polarizada.Resultados:
demonstraram que, embora com algum grau de variação, o sistema DIAGNOdent® foi capaz de detectar as descalcificações semelhantemente àqueles reconhecidos por microscopia de luz polarizada, estabelecendo um padrão razoável de equivalência de leituras.Conclusão:
os valores médios encontrados para o DIAGNOdent® demonstraram um coeficiente de correlação de Pearson de 0,63 com relação aos valores das leituras microscópicas.ABSTRACT
Aim:
evaluate the correlation between the artificial in vitro enamel decalcification through DIAGNOdent® laser and through optic microscopic with polarized light.Methodology:
for this research, 25 bovine teeth had been exposed to an artificial decay environment during one hour, two times a day, for 35 days. After wards, DIAGNOdent® laser has been used to read the fluorescence from the enemel areas without decalcification (for calibration) and to evaluate the non-mineralized artificially. After the fluorescence readings regions of laser read were cut into sections of about 400μm and evaluated by polarized light microscopy.Results:
the results had demonstrated that, even with some degree of variation, the DIAGNOdent® system was capable of recognizing the decalcification, establishing regular equivalence of standard readings such as light polarized microscopy.Conclusion:
the average values found for DIAGNOdent® laser had demonstrated a 0,63 coefficient of correlation of Pearson to the values of microscopically readings.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
In Vitro Techniques
/
Tooth Demineralization
/
Dental Caries
/
Lasers
/
Microscopy, Polarization
Limits:
Animals
Language:
Portuguese
Journal:
Odonto (Säo Bernardo do Campo)
Journal subject:
Dentistry
Year:
2010
Type:
Article
Affiliation country:
Brazil
Institution/Affiliation country:
Universidade Estadual de Maringá/BR
/
Universidade Federal do Rio Grande do Sul/BR
Similar
MEDLINE
...
LILACS
LIS