Avaliação do teor de Atenolol em comprimidos divididos com faca caseira e aparelho cortador / Evaluation of the content of Atenolol tablets divided with a knife and homemade machine cutter / Evaluación de la proporción de Atenolol en comprimidos divididos con cuchillo casero y con cortador
Auricchio, Mariangela Tirico; Yano, Helena Miyoco; Santos, Ana Paula; Bugno, Adriana.
  • Auricchio, Mariangela Tirico; Instituto Adolfo Lutz. Serviço de Medicamentos. São Paulo. BR
  • Yano, Helena Miyoco; Instituto Adolfo Lutz. Serviço de Medicamentos. São Paulo. BR
  • Santos, Ana Paula; Instituto Adolfo Lutz. Serviço de Medicamentos. São Paulo. BR
  • Bugno, Adriana; Instituto Adolfo Lutz. Serviço de Medicamentos. São Paulo. BR
Acta paul. enferm ; 24(1): 74-79, 2011. ilus, tab
Article in Portuguese | LILACS, BDENF | ID: lil-578377
RESUMO

OBJETIVO:

Avaliar se o teor de Atenolol em fragmentos de comprimidos nas dosagens de 100 mg, 50 mg e 25 mg partidos em duas e quatro partes com auxílio de faca caseira e de aparelho cortador de comprimidos é diferente em função do modo como a divisão é realizada.

MÉTODOS:

Os comprimidos íntegros foram divididos com faca caseira e com aparelho cortador de comprimidos, e os teores de Atenolol foram determinados em todos os fragmentos.

RESULTADOS:

Não houve diferença significativa entre os teores obtidos, após divisão dos comprimidos com faca caseira ou com aparelho cortador, apesar da divisão levar a acentuada dispersão dos teores entre os fragmentos, na divisão em metade, a dispersão dos resultados deu-se entre 7,8 por cento e 12,1 por cento, e quando divididos em quatro partes, foi entre 9,2 por cento e 21,1 por cento, indicando a possibilidade de comprometer a eficácia do tratamento dos pacientes independente de como a divisão foi feita.

CONCLUSÃO:

Os resultados indicaram a ocorrência de dispersão maior do que a estabelecida para garantir uniformidade da dose recebida a cada administração do medicamento independente da forma de realizar a divisão, seja por meio de faca caseira ou com aparelho cortador de comprimidos.
ABSTRACT

OBJECTIVE:

To evaluate whether the content of Atenolol on fragments of tablets in dosages of 100 mg, 50 mg and 25 mg broken into four parts with the aid of homemade knife and cutter unit tablets is different, depending on how the division is performed.

METHODS:

The intact tablets were divided with a knife and with a homemade pill cutter device, and the concentrations of Atenolol were determined in all fragments.

RESULTS:

No significant difference existed between the levels of Atenolol obtained after splitting the tablets with the homemade knife or the pill cutter device, although the division led to severe levels of dispersal among fragments. When divided in half, the dispersion of results was between 7 percent and 12.1 percent, and when divided into four parts, it was between 9.2 percent and 21.1 percent, indicating the possibility of compromising the effectiveness of treating patients regardless of how the division was made.

CONCLUSION:

The results indicated a greater dispersion than would be acceptable to guarantee a uniform dose received at each drug administration, regardless of the way the division was performed, either by phone or homemade knife cutter pills.
RESUMEN

OBJETIVO:

Evaluar si la proporción de Atenolol en fragmentos de comprimidos en las dosis de 100 mg, 50 mg y 25 mg partidos en dos y cuatro partes con la ayuda de un cuchillo casero y de un cortador de comprimidos es diferente en función al modo cómo se realiza la división.

MÉTODOS:

Los comprimidos enteros fueron divididos con un cuchillo casero y con un cortador de comprimidos, siendo determinadas las proporciones de Atenolol en todos los fragmentos.

RESULTADOS:

No hubo diferencia significativa entre las proporciones obtenidas, después de la división de los comprimidos tanto con cuchillo casero como con el cortador. A pesar de que la división lleve una acentuada dispersión de las proporciones entre los fragmentos, en la división por la mitad, la dispersión de los resultados se dió entre 7,8 por ciento y 12,1 por ciento, y cuando fueron divididos en cuatro partes, fue entre 9,2 por ciento y 21,1 por ciento, indicando la posibilidad de comprometer la eficacia del tratamiento de los pacientes independiente de cómo haya sido realizada la división.

CONCLUSIÓN:

Los resultados indicaron la ocurrencia de mayor dispersión de la establecida para garantizar la uniformidad de la dosis recibida en cada administración del medicamento independiente de la forma de realizar la división, sea por medio de un cuchillo casero o un cortador de comprimidos.


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Acta paul. enferm Journal subject: Nursing Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto Adolfo Lutz/BR