Your browser doesn't support javascript.
loading
Método da eletrorresistividade aplicado no monitoramento temporal da pluma de contaminação em área de disposição de resíduos sólidos urbanos / Electrical resistivity method applied in the temporal monitoring of the contamination plume in disposal area of urban solid waste
Bortolin, José Ricardo Melges; Malagutti Filho, Walter.
  • Bortolin, José Ricardo Melges; Unesp. Instituto de Geociências e Ciências Exatas. Rio Claro. BR
  • Malagutti Filho, Walter; Unesp. Instituto de Geociências e Ciências Exatas. Rio Claro. BR
Eng. sanit. ambient ; 15(4): 367-374, out.-dez. 2010. ilus
Article in Portuguese | LILACS | ID: lil-578702
RESUMO
Este trabalho apresenta os resultados do monitoramento temporal da pluma de contaminação do aterro controlado de Rio Claro, São Paulo, por meio do método da eletrorresistividade, que consistiu na comparação dos resultados de várias seções de imageamento elétrico, executados nos mesmo locais, nos anos de 1999 e 2008. Zonas de baixa resistividade, com valores menores ou iguais a 50 Ω.m, foram associadas à contaminação por chorume. Desse modo, foi possível identificar dois sentidos do fluxo da pluma: (1) em direção ao sul, e (2) em direção ao oeste. Nas seções de 2008, a pluma de contaminação apresentou-se mais extensa e profunda do que em 1999. De forma complementar, as sondagens elétricas verticais aferiram a profundidade do nível freático e o sentido do fluxo d'água, subsidiando a interpretação dos imageamentos.
ABSTRACT
This paper shows the results of a periodical monitoring of the contamination plume of a controlled landfill in Rio Claro, São Paulo, Brazil, using electrical resistivity geophysical method. The monitoring consisted on comparing the results of several electrical sections, performed at the same location, in the years of 1999 and 2008. Low resistivity zones, with values lower than or equal to 50 Ω.m, have been associated to contamination by leachate. Thus, it was possible to identify two directions for the contamination flows: (1) toward south, and (2) toward west. In the results of 2008, the contamination plume was more extensive and profound than in 1999. The vertical electrical soundings indicated the water table depth and the water flow directions, helping the interpretation of results of the electrical profiles.


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Unesp/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2010 Type: Article Affiliation country: Brazil Institution/Affiliation country: Unesp/BR