Estudio piloto de medidas antropométricas de la mano y fuerzasde prensión: aplicables al diseño de herramientas manuales / Pilot study of anthropometric measurements of the hand and grip strengths: applicable to manual tool design
Cienc. Trab
;
13(39): 1-5, ene.-mar. 2011. ilus, tab
Article
in Spanish
| LILACS
| ID: lil-583089
RESUMEN
Objetivo:
El objetivo de este artículo es presentar resultados de un estudio no experimental, descriptivo y transversal este estudio describe fuerzas de prensión dígito-palmar completa (agarre) y dimensiones antropométricas de mano de una muestra de trabajadores de mantención.Método:
Muestra de 36 trabajadores de áreas de mantención, de 3 complejos hospitalarios del sector sur de Santiago y trabajadores de la Facultad de Medicina de la Universidad de Chile. Se evaluó, en cada sujeto, 13 dimensiones antropométricas de mano y fuerzas de prensión máxima en 5 distancias de agarre previamente determinadas. Para la medición de las variables se utiliza cinta métrica de medición y dinamómetro Dynatronics.Resultados:
La distancia de agarre de 4,76 cm representa la medida donde se ejecuta la mayor fuerza prensión dígito-palmar completa (posición 2 de dinamómetro Dynatronics). La caracterización de las 13 medidas antropométricas de mano se representa mediante medidas de tendencia central.Conclusión:
Los resultados de este estudio constituyen una base preliminar para proveer información relevante respecto a antropometría de mano y fuerzas de prensión dígito-palmar (agarre) para el diseño y selección de herramientas de uso manual, a fin y efecto de obtener sistemas más seguros para las personas y eficientes en la ejecución de tareas específicas.ABSTRACT
Objective:
The aim of this article is to present results of a nonexperimental,descriptive, cross-sectional study. Full digital palmar grip strengths and hand anthropometric measurements of a sample of maintenance personnel are described in this study.Method:
Sample is composed of 36 maintenance workers from 3 hospital centers located in the southern part of Santiago and workers from the Medical School of the Universidad de Chile. In each subject, 13 hand anthropometric measurements were taken and then maximum grip strengths in 5 previously determined grip distances were measured. A tape measurer and Dynatronics dynamometer were used for measuring variables.Results:
The highest full digital palmar grip strength was registered in a grip distance of 4,76 cm (position 2 of the Dynatronics dynamometer). The 13 hand anthropometric measurements were represented by measures of central tendency.Conclusion:
Results of this study constitute a preliminary base to provide significant information regarding hand anthropometry and digital palmar grip strengths for the design and selection of manual tools, thus obtaining more secure and efficient systems for workers in specific tasks.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Anthropometry
/
Hand Strength
/
Muscle Strength
/
Hand
Type of study:
Observational study
/
Prevalence study
/
Risk factors
Limits:
Adult
/
Humans
Country/Region as subject:
South America
/
Chile
Language:
Spanish
Journal:
Cienc. Trab
Journal subject:
Occupational Medicine
/
Public Health
Year:
2011
Type:
Article
Affiliation country:
Chile
Institution/Affiliation country:
Universidad de Chile/CL
Similar
MEDLINE
...
LILACS
LIS