Efectividad del cálculo del poder dióptrico de la lente intraocular con interferometría parcialmente coherente / Effectiveness of the intraocular lens power calculation using the partial coherent interferometry
Santiesteban García, Imalvet; Pérez Candelaria, Eneida; Capote Cabrera, Armando; Montero Díaz, Eric; Pedroso Llanes, Alina; Rodríguez Suárez, Belkys.
  • Santiesteban García, Imalvet; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
  • Pérez Candelaria, Eneida; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
  • Capote Cabrera, Armando; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
  • Montero Díaz, Eric; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
  • Pedroso Llanes, Alina; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
  • Rodríguez Suárez, Belkys; Instituto Cubano de Oftalmología Ramón Pando Ferrer. Ciudad de La Habana. CU
Rev. cuba. oftalmol ; 23(1): 88-99, ene.-jun. 2010.
Article in Spanish | LILACS | ID: lil-584986
RESUMEN
OBJETIVO: Comparar la efectividad del cálculo del poder dióptrico de la lente intraocular con IOL Master y el método de biometría por aplanación convencional. MÉTODOS: Se seleccionó una muestra de 100 ojos (pacientes) mediante un muestreo simple aleatorio, en el Servicio de Catarata del Centro de Microcirugía Ocular, con diagnóstico de catarata unilateral o bilateral en la consulta preoperatorio, desde marzo hasta septiembre de 2006. Se clasificaron en dos grupos según el método utilizado para el cálculo de la lente intraocular. Se analizaron las variables: longitud axial media preoperatoria, promedio queratométrico preoperatorio, componente esférico esperado y obtenido, agudeza visual sin corrección y mejor agudeza visual corregida preoperatoria y posoperatoria. El análisis estadístico de los resultados se realizó mediante un análisis de varianza, la prueba t de Student de comparación de medias para datos pareados y chi cuadrado. Se utilizó un nivel de confiabilidad de 95 por ciento. RESULTADOS: Entre los principales resultados se encontró que la diferencia de las longitudes axiales entre los métodos IOL Master y biometría por aplanación A-Scan fue estadísticamente significativa. La agudeza visual sin corrección aumentó cuatro líneas y la mejor agudeza visual corregida seis líneas en el posoperatorio de los pacientes del grupo I. El 90 por ciento de los pacientes del grupo I, o sea, los calculados con IOL Master quedaron en la emetropía en cuanto al componente esférico. CONCLUSIONES: Se evidenció una diferencia significativa e inferior a la encontrada en estudios internacionales entre las longitudes axiales preoperatorias halladas mediante los métodos IOL Master y biometría por aplanación; resultaron superiores las calculadas por IOL Master. Se obtuvo ganancia en las líneas de la Cartilla de Snellen tanto de la agudeza visual sin corrección como la mejor agudeza visual corregida en ambos grupos (superior en el grupo II). Predomina ron los resultados refrac...
ABSTRACT
OBJECTIVE: to compare the effectiveness of the intraocular lens dioptric power calculation using IOL Master and the conventional applanation biometry. METHODS: A sample of 100 eyes (patients), diagnosed with unilateral or bilateral cataract in the preoperative consultation service, was selected through simple random sampling in the Ocular Microsurgery Center in the period from March to September, 2006. They were divided into two groups based on the method for intraocular lens calculation. The variables were preoperative mean axial length, preoperative keratometric average, expected and obtained spheral component, visual acuity without correction and better corrected visual acuity preoperatively and postoperatively. The statistical analysis of the results was made by variance analysis, Student's t test for paired mean comparisons and Chi square. The confidence level of 95 percent was used. RESULTS: Among the main results, it was found that the axial length differences between IOL Master and A-Scan applanation biometry was statistically significant. Visual acuity without correction increased 4 lines and the best corrected visual acuity increased 6 lines in the postoperative period of the group I patients. Ninety percent of the group I patients, whose visual acuity was calculated with IOL Master, reached emetropia in terms of the spheral component. CONCLUSIONS: A significant difference but lower than that found in the international studies among the preoperative axial lengths calculated through ILO Master and applanation biometry were evinced. The differences were higher in the lenghts calculated by IOL Master. There was improvement in the number of lines of Snellen´s chart both in the visual acuity without correction and the better corrected visual acuity in the two groups; being better in group II. The refractive results tending to emetropy prevailed, taking into consideration the spheral component reached in both groups, which were also higher in group I
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Biometry / Lenses, Intraocular / Microscopy, Interference Type of study: Controlled clinical trial / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Biometry / Lenses, Intraocular / Microscopy, Interference Type of study: Controlled clinical trial / Observational study Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU