Your browser doesn't support javascript.
loading
Estudo de três estratégias de ventilação artificial protetora: alta frequência, baixa frequência e baixa frequência associada à insuflação de gás traqueal, em modelo experimental de SARA / Comparing three protective mechanical ventilation strategies, HFOV, low-frequency-ventilation, and low-frequency-ventilation with TGI, in an ARDS experimental model
São Paulo; s.n; 2006. 148 p.
Thesis in Portuguese | LILACS | ID: lil-587141
RESUMO

Introdução:

Um dos principais objetivos na SARA é encontrar a melhor estratégia protetora de ventilação mecânica que minimize o stress pulmonar e otimize as trocas gasosas. Teoricamente, estas duas metas podem ser obtidas simultaneamente, evitando-se a hiperdistensão e colapso cíclico de unidades alveolares instáveis. Numa tentativa de radicalizar a minimização da hiperdistensão e da pressão motriz inspiratória, duas estratégias podem ser propostas o uso da ventilação de alta freqüência oscilatória (HFOV) e o uso da insuflação intra-traqueal de gás (TGI), esta última associada à hipercapnia permissiva e baixas freqüências respiratórias.

Objetivo:

identificar qual (quais) entre as três estratégias de ventilação mecânica, HFOV, TGI e ventilação protetora de baixa freqüência (VP volume corrente ~6 mL/kg), foi (foram) a (s) mais protetora (s) em um modelo de SARA em coelhos, durante seis horas de ventilação mecânica. Material e

métodos:

Os animais (n = 45) foram submetidos a repetidas lavagens pulmonar até uma PaO2 < 100 mmHg. Imediatamente após a injuria pulmonar, foi obtida uma curva P/V para calculo do trabalho inspiratório e energia dissipada durante insuflação pulmonar. Em seguida, os animais foram randomizados em um dos três grupos HFOV, VP ou TGI. O PEEP ou PMEAN ideais foram obtidos através de uma curva PEEP/PaO2 (ou PMEAN/PaO2) que foi precedida por uma manobra de recrutamento. Os animais dos grupos VP e TGI foram inicialmente ventilados em PCV com um delta de pressão = 8 cmH2O e freqüência = 60 resp/min. A única diferença inicial entre os dois foi que o grupo TGI possuía um fluxo traqueal continuo = 1 L/min. Os animais do grupo HFOV foram inicialmente ventilados com uma amplitude de pressão = 45 cmH2O e freqüência = 10 Hz. Todos os animais foram ventilados com uma FiO2 = 1.0. Os deltas de pressão (ou pressão motriz)...
ABSTRACT

Introduction:

One of the major goals in ARDS is to find the best protective mechanical ventilation strategy, which minimizes lung stress and optimizes gas exchange. Theoretically, these two goals can be accomplished by simultaneously avoiding alveolar overdistension and cyclic collapse of unstable alveolar units. Pushing further the rationale of this strategy, two new strategies have been proposed high frequency oscillatory mechanical ventilation (HFOV) and intra-tracheal gas insufflation (TGI) associated with permissive hypercapnia and conventional frequencies.

Objective:

To determine which of the three protective modalities of mechanical ventilation, HFOV, low-frequency-protective ventilation (LFV), or LFV associated with tracheal gas insufflation (TGI), was the most protective strategy in an ARDS rabbit model during six hours of mechanical ventilation. Material and

methods:

The animals (n = 45) were submitted to repeated saline lavage until PaO2 < 100 mmHg. Immediately after lung injury, a P/V curve was obtained to calculate inspiratory/expiratory work and energy dissipated during lung inflation. Thereafter, the animals were randomized into one of three groups LFV, HFOV or TGI. The optimal PEEP or PMEAN was obtained during a PEEP/PaO2 (or PMEAN/PaO2) curve which was preceded by a recruiting maneuver. The animals of the LFV and TGI groups were initially ventilated in PCV with diving pressure = 8 cmH2O and frequency = 60 b/m. The only initial difference between these two arms was that the TGI group had a continuous tracheal flow = 1 L/min. The animals in the HFOV were initially ventilated with an oscillatory pressure amplitude = 45 cmH2O and frequency = 10 Hz. All animals were ventilated with FiO2 = 1.0. Driving pressure was then adjusted in LFV and TGI groups to maintain a PaCO2 = 90-110 mmHg, while in HFO the pressure amplitude was adjusted to maintain a PaCO2 = 45-55 mmHg. At the end of the experiment, after 6 hours of ventilation...
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Rabbits / Respiration, Artificial / Respiratory Distress Syndrome / High-Frequency Ventilation / Case-Control Studies / Lung Limits: Animals Language: Portuguese Year: 2006 Type: Thesis

Similar

MEDLINE

...
LILACS

LIS