Wastewater from a hardboard mill characterized by a high organic content (15-30 g/L COD) was studied in a bench scale sequential aerated system in order to define a start up strategy. Inlet COD concentration varied from 0.5 to 25 g/L and the hydraulic retention time was maintained at 5 days. The sequential system proposed could reduce BOD, COD, TSS and phenol over 90 percent except when the inlet COD concentration was lower than 25 g/L.
RESUMO
Água residual proveniente de uma indústria de tabuleiro de fibra dura caracterizada por ter um elevado conteúdo orgânico (15-30 g/L DQO) foi estudada utilizando um sistema arejado seqüêncial de forma a definir uma estratégia de start up. A concentração de DQO na entrada do sistema variou na faixa de 0,5-25 g/L e o tempo de residência hidráulico foi mantido em 5 dias. O sistema seqüêncial proposto reduziu DBO, DQO, SST e fenol sobre 90 por cento quando a concentração de DQO na entrada foi menor a 25 g/L.