Your browser doesn't support javascript.
loading
Comparación de los grados de lesión en las estructuras cocleares según los tipos de electrodos perimodiolares insertados y el tamaño de la cocleostomía realizada / Comparison of intracochlear damage according to the type of perimodiolar electrodes inserted and the size of the cochleostomy performed
Guzmán Durán, José Eduardo; Hernández, Santiago; Jaramillo, Rafael; Revollo, Francisco J; Prieto Rivera, José Alberto.
  • Guzmán Durán, José Eduardo; Universidad Militar Nueva Granada. Hospital Universitario Clínica San Rafael. Hospital Militar Central. Hospital central de la Policía. Bogotá. CO
  • Hernández, Santiago; Clinica de Marly. Bogotá. CO
  • Jaramillo, Rafael; Universidad Militar Nueva Granada. Bogotá. CO
  • Revollo, Francisco J; Universidad Militar Nueva Granada. Santa Marta. CO
  • Prieto Rivera, José Alberto; Hospital Universitario Clinica San Rafael. Bogotá. CO
Acta otorrinolaringol. cir. cabeza cuello ; 39(3): 111-157, sept. 2011.
Article in Spanish | LILACS | ID: lil-605815
RESUMEN
Comparar los diferentes grados del trauma en las estructuras anatómicas intracocleares luego de la inserción de tres diferentes electrodos erimodeolares insertados con dos tamaños diferentes de cocleostomías. Trauma valorado fluoroscópicamente y anatómico microscópico. Diseño del estudio. Estudio experimental con dos variables. Métodos. Se realizaron cocleostomías de 1.3 y 2 mm en 15 huesos temporales de cadáver, estos fueron implantados bajo visión fluoroscopia con uno de los siguientes electrodos perimodeolares electrodo Nucleus 24 contur (Cochlear Implant System), electrodo Hi Focus Helix (Advanced Bionics), electrodo Combi 40 + (Medel). Se efectúan microcortes en 15 cócleas con el electrodo inserto, teniendo 3 cócleas como grupo control sin implantar. Cada cóclea fue analizada con otomicroscopio a un aumento 16x, valorando cualquier posible trauma durante la inserción.

Resultados:

Se encontraron tres diferentes grados de alteraciones observadas durante la inserción, en algunas fue solamente observada en la visión fluoroscópica; así mismo no se encontraron diferencias estadísticamente significativas entre el tipo de electrodo y el tamaño de la colostomía.

Conclusiones:

La inserción de los electrodos perimodeolares crean diferentes grados de trauma histomorfológicos en la cóclea; sin embargo, este modelo aunque es efectivo no es el óptimo para documentar los grados de lesión coclear. La visión fluoroscópica de la inserción puede proveer una ubicación inicial adecuada del lugar de la lesión. Al parecer no hay una relación directa entre lo observado fluoroscópicamente y los hallazgos anatómicos cocleares luego de analizar los microcortes. Significancia clínica del estudio El implante in vitro de huesos temporales bajo visión fluoroscópica es una poderosa herramienta académica para el entrenamiento de cirujanos en el campo de la otología.
ABSTRACT
Problem addressed. To compare the different degrees of injury in the intracochlear structures using three different perimodiolar electrode arrays inserted and two sizes of cochleostomies. Study design. Experimental study with two variables. Methods. Cochleostomies of 1.3 and 2 millimeters were used in 15 temporal bones and then were implanted under fluoroscopic vision with one of the following perimodiolar electrode arrays electrode nucleus 24 contour (Cochlear Implant System), electrode hi focus helix (Advanced Bionics), electrode combi 40 + (MED-EL). Micro slices of the 15 study cochleae with the electrode array in place and 3 more control cochleae were studied under 16x looking for any possible trauma during insertion. Results. There were different degrees of injuries observed during insertion, as well as some resistance documented under fluoroscopic vision in some of the temporal bones. However, there were no statistical differences either with the different type of electrodes or the different sizes of cochleostomy. Conclusions. Insertion of perimodiolar electrodes assumes some degree of histological cochlear injury. Nevertheless, the study model used was not the most favorable method to document the different degrees of intracochlear lesion. The video fluoroscopy during the insertion of the electrode array showed the possible location of the commencement of a supposed lesion. There was no concurrence between the video fluoroscopic findings and the location and degrees of intracochlear damage observed in the anatomical microcuts. Clinical significance of study. The in vitro insertion of a cochlear implant assisted by a videofluoroscopy could be considered a useful tool for surgeons in training.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Cochlear Diseases / Cochlear Implants Type of study: Prognostic study Language: Spanish Journal: Acta otorrinolaringol. cir. cabeza cuello Journal subject: Lesäes do Pesco‡o / Otolaringologia / Otorrinolaringopatias / Traumatismos Craniocerebrais Year: 2011 Type: Article Affiliation country: Colombia Institution/Affiliation country: Clinica de Marly/CO / Hospital Universitario Clinica San Rafael/CO / Universidad Militar Nueva Granada/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Cochlear Diseases / Cochlear Implants Type of study: Prognostic study Language: Spanish Journal: Acta otorrinolaringol. cir. cabeza cuello Journal subject: Lesäes do Pesco‡o / Otolaringologia / Otorrinolaringopatias / Traumatismos Craniocerebrais Year: 2011 Type: Article Affiliation country: Colombia Institution/Affiliation country: Clinica de Marly/CO / Hospital Universitario Clinica San Rafael/CO / Universidad Militar Nueva Granada/CO