Your browser doesn't support javascript.
loading
Posicionamento do componente acetabular na artroplastia total do quadril com e sem o auxílio de um sistema de navegação computadorizado: estudo comparativo prospectivo randomizado / Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomised and controlled study
São Paulo; s.n; 2011. [159] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-609398
RESUMO
Em um estudo prospectivo e randomizado sobre o posicionamento do componente acetabular na artroplastia total do quadril, 20 quadris foram operados com o auxílio da navegação livre de métodos de imagem e 20 quadris foram operados através do método convencional. Todas as cirurgias foram realizadas pelo mesmo cirurgião com o paciente em decúbito lateral. A avaliação do posicionamento foi feita através da medição tomográfica pós-operatória dos ângulos de anteversão e inclinação cirúrgicos e análise da zona de segurança. Os resultados obtidos foram similares em todas as comparações: anteversão média de 17,4o no grupo navegado e 14,5o no grupo convencional (p=0,215), inclinação média de 41,7o no grupo navegado e 42,2o no grupo convencional (p=0,633), desvio médio do objetivo da anteversão (15o) de 5,5o no grupo navegado e 6,6o no grupo convencional (p=0,429), desvio médio do objetivo da inclinação (40o) de 3o no grupo navegado e 3,2o no grupo convencional (p=0,783) e localização dentro da zona de segurança de 90% no grupo navegado e 80% no grupo convencional (p=0,661). A avaliação tomográfica pós-operatória do posicionamento acetabular na artroplastia total de quadril realizada com o paciente em decúbito lateral foi semelhante ao se comparar a técnica navegada com a técnica convencional.
ABSTRACT
In a prospective and randomised study of the acetabular component position in total hip arthroplasty, 20 hips were operated using imageless navigation and 20 hips were operated using the conventional method. The same surgeon performed all the operations with the patient in the lateral position. The correct position of the acetabular component was evaluated with computed tomography performed after the surgeries, measuring the operative anteversion angle and the operative inclination angle and determining the cases inside the safe zone. The results were similar in all the analyses: a mean anteversion of 17.4o in the navigated group and 14.5o in the conventional group (p=0.215), a mean inclination of 41.7o in the navigated group and 42.2o in the conventional group (p=0.633), a mean deviation from the desired anteversion (15o) of 5.5o in the navigated group and 6.6o in the conventional group (p=0.429), a mean deviation from the desired inclination (40o) of 3o in the navigated group and 3.2o in the conventional group (p=0.783), and location inside the safe zone of 90% in the navigated group and 80% in the conventional group (p=0.661). The acetabular component positions tomography analyses in total hip arthroplasty, performed with the patient in the lateral position, were similar whether using imageless navigation or performing it conventionally.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Arthroplasty / Hip / Acetabulum Type of study: Controlled clinical trial / Observational study Limits: Adult / Female / Humans / Male Language: Portuguese Year: 2011 Type: Thesis

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Arthroplasty / Hip / Acetabulum Type of study: Controlled clinical trial / Observational study Limits: Adult / Female / Humans / Male Language: Portuguese Year: 2011 Type: Thesis