Your browser doesn't support javascript.
loading
Tratamento cirúrgico de fibrilação atrial utilizando ablação com radiofrequência bipolar em doença mitral reumática / Surgical treatment of atrial fibrillation using bipolar radiofrequency ablation in rheumatic mitral disease
Canale, Leonardo Secchin; Colafranceschi, Alexandre Siciliano; Monteiro, Andrey José Oliveira; Marques, Bruno Miranda; Canale, Clara Secchin; Koehler, Ernesto Chavez; Cruz Filho, Fernando Eugênio dos Santos.
  • Canale, Leonardo Secchin; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Colafranceschi, Alexandre Siciliano; Instituto Nacional de Cardiologia. Divisão de Procedimentos Cirúrgicos. Rio de Janeiro. BR
  • Monteiro, Andrey José Oliveira; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Marques, Bruno Miranda; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Canale, Clara Secchin; Universidade Federal do Rio de Janeiro. Rio de Janeiro. BR
  • Koehler, Ernesto Chavez; Instituto Nacional de Cardiologia. Rio de Janeiro. BR
  • Cruz Filho, Fernando Eugênio dos Santos; Instituto Nacional de Cardiologia. Divisão de Arritmologia. Rio de Janeiro. BR
Rev. bras. cir. cardiovasc ; 26(4): 565-572, out.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-614748
RESUMO

OBJETIVO:

Avaliar a eficácia do tratamento cirúrgico da fibrilação atrial (FA) utilizando ablação com radiofrequência bipolar durante cirurgia cardíaca de procedimentos mitrais de etiologia reumática.

MÉTODOS:

Foram avaliados, retrospectivamente, os prontuários e exames de 53 pacientes submetidos à cirurgia valvar mitral, com ou sem cirurgia tricúspide ou aórtica associada, em que foi realizada ablação de FA utilizando radiofrequência bipolar. Trinta e quatro (64 por cento) pacientes eram mulheres e a idade variou de 27 a 72 anos (média 49,3 anos ± 10,7 anos). O tempo médio de FA relatado foi de 41 meses (variou de 3 a 192 meses). O tipo de FA apresentado foi paroxística em oito pacientes, persistente em três, permanente em 42. O átrio esquerdo apresentava tamanho médio de 52,9 ± 8,5 mm. As cirurgias realizadas foram 47 trocas de valva mitral e seis plastias mitrais. O seguimento eletrocardiográfico foi completo em 83 por cento dos pacientes, ao final de 14 meses. Informações adicionais oriundas de Holter 24h foram exploradas.

RESULTADOS:

Ocorreram sete (13 por cento) óbitos per-operatórios e a sobrevida após 14 meses foi de 87 por cento. Os ritmos cardíacos encontrados após um ano de cirurgia foram sinusal em 25 (66 por cento) pacientes, FA em sete (18 por cento), Flutter em cinco (13 por cento), Juncional em um (3 por cento).

CONCLUSÃO:

O uso de radiofrequência bipolar para tratamento de FA em pacientes submetidos à cirurgia valvar mitral de origem reumática é efetivo no controle da arritmia em 68 por cento dos pacientes, após 14 meses.
ABSTRACT

OBJECTIVE:

To analyze the effectiveness of surgical treatment of atrial fibrillation (AF) using bipolar radiofrequency ablation during mitral valve procedures of rheumatic etiology in heart surgery.

METHODS:

We retrospectively reviewed medical registries of 53 patients submitted to atrial ablation with bipolar radiofrequency energy during mitral valve surgery. Thirty four (64 percent) patients were women and the age varied from 27 to 72 years old (average 49.3 ± 10.7 years). Aortic and/or tricuspid procedures were also present in 36 (68 percent) patients. Average time of reported atrial fibrillation was 41 months (from 3 to 192 months). Type of AF was classified as paroxysmal in 8 patients, persistent in 3, permanent in 42. Left atrium had an average size of 52.9 ± 8.5 mm. The surgeries in these series were 47 mitral valve replacements and 6 mitral valve repairs. Eletrocardiografic follow up was 83 percent complete in 14 months. Data from 24h Holter were explored.

RESULTS:

Seven (13 percent) perioperative deaths were observed and survival after 14 months was 87 percent. Observed heart rhythm after 1 year of surgery was sinus rhythm in 25 (66 percent) patients, AF in 7 (18 percent), flutter in 7 (13 percent), junctional in 1 (3 percent).

CONCLUSION:

Bipolar radiofrequency ablation in patients submitted to mitral valve surgery of rheumatic etiology is effective in converting to sinus rhythm in 68 percent of patients after 14 months.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Rheumatic Heart Disease / Atrial Fibrillation / Catheter Ablation / Heart Rate / Heart Valve Diseases / Mitral Valve Type of study: Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto Nacional de Cardiologia/BR / Universidade Federal do Rio de Janeiro/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Rheumatic Heart Disease / Atrial Fibrillation / Catheter Ablation / Heart Rate / Heart Valve Diseases / Mitral Valve Type of study: Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2011 Type: Article Affiliation country: Brazil Institution/Affiliation country: Instituto Nacional de Cardiologia/BR / Universidade Federal do Rio de Janeiro/BR