Your browser doesn't support javascript.
loading
Autofluorescencia de fondo en pacientes con coriorretinopatía serosa central / Fundus autofluorescence in patients with central serous chorioretinopathy
Santana Alas, Eva R; Arencibia González, Danaides B; Gonzales Díaz, Rafael; Garcés Fernández, Ailén; Lapido Polanco, Suzel; Velázquez Villares, Yolanda.
  • Santana Alas, Eva R; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Arencibia González, Danaides B; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Gonzales Díaz, Rafael; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Garcés Fernández, Ailén; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Lapido Polanco, Suzel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Velázquez Villares, Yolanda; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. oftalmol ; 23(supl.2): 770-780, 2010.
Article in Spanish | LILACS | ID: lil-615615
RESUMEN

OBJETIVO:

Describir las características de la autofluorescencia de fondo en pacientes con coriorretinopatía serosa central y determinar su relación con las alteraciones funcionales y anatómicas de la región macular.

MÉTODOS:

Estudio descriptivo, transversal en 21 ojos (21 pacientes) con coriorretinopatia serosa central en diferentes estadios evolutivos. Se identificó el patrón de autofluorescencia en el área de desprendimiento neurosensorial, se usó el angiógrafo retinal de Heidelberg a 30°. Con la tomografía de coherencia óptica, se midió el grosor macular central y se describieron los cambios anatómicos. A 12 de los pacientes se les realizó angiografía fluoresceínica en el Angiógrafo Retinal de Heidelberg.

RESULTADOS:

Se encontró hipoautofluorescencia en el 51,90 por ciento, hiperautofluorescencia en el 42,86 por ciento; coexisten ambos en el 4,76 por ciento. No hubo diferencia significativa entre la hiperautofluorescencia y la hipoautofluorescencia en cuanto a agudeza visual mejor corregida (media de 0,43 y 0,49, respectivamente; p= 0,184), ni respecto al grosor macular central (media de 371,3 µm y 388,1 µm , respectivamente; p= 0,867), pero si entre el tiempo de evolución y el patrón de autofluorescencia, (p= 0, 023). En ojos con hiperautofluorescencia se observó por tomografía de coherencia óptica irregularidad en capas externas y en epitelio pigmentario de la retina. El 83,3 por ciento de los casos que requirieron angiografó fluoresceínica presentaron hiperfluorescencia que coincidió con la hipoautofluorescencia del sitio de fuga.

CONCLUSIONES:

En la coriorretinopatía serosa central se encuentran diferentes patrones de autofluorescencia, los que reflejan cambios en la retina externa y epitelio pigmentario de la retina. La autofluorescencia puede ayudar a identificar el sitio de difusión focal en el epitelio pigmentario de la retina
ABSTRACT

OBJECTIVES:

To describe the peculiarities of the Fundus Autofluorecense in patiens with Central Serous Chorioretinopathy (CSC), and determine the relationship with functional and anatomic disturbances of the macular region.

METHODS:

Cross-sectional descriptive study performed in 21 eyes (21 patients), suffering from central serous chorioretinopathy in different statings. The pattern of autofluorecense in the neurosensoral detachment was detected with the Heidelberg´s Retinal Angiograph (HRA2) on 30° position. The optical coherence tomography (3D-OCT-Topcon) (Nidek) measured the central macular thickness and exposed the anatomic changes. Flourescein angiografy with HRA2 was performed on 12 patients.

RESULTS:

Hypoautofluorescense was detected in 51,90 percent and hyperautofluorescense in 42,86 percent of cases respectively; both disorders were present in 4,76 percent of the patients. There was no significant difference between hyperautofluorecense and hypoautofluorescense as to the best corrected visual acuity (mean of 0,43 and 0,49, respectively; p= 0.184), and the central macular thickness (mean of 371.3 µm and 388.1 µm , respectively; p= 0.867). However, the difference was significant between time of evolution and the pattern of autoflorescence (p= 0.023). In those eyes affected by hyperautofluorescense, the optical coherence tomography allowed observing irregularities on the external layers and on the retinal pigmentary epithelium. The 83,3 percent of cases who needed AGF presented with hyperautofluorescense that matched with hypoautofluorescence in the leakage site.

CONCLUSIONS:

In the central serous chorioretinopathy, different autofluorescense patterns may be found that reflect changes in the external retina and the retinal pigmentary epithelium. The autofluorescense may help to identify the focal diffusion site
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Fluorescein Angiography / Chorioretinitis Type of study: Observational study / Prevalence study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Fluorescein Angiography / Chorioretinitis Type of study: Observational study / Prevalence study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Spanish Journal: Rev. cuba. oftalmol Journal subject: Ophthalmology Year: 2010 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU