Your browser doesn't support javascript.
loading
Confiabilidad y concordancia de dos escalas de lectura de baciloscopias para clasificación y seguimiento del tratamiento con múltiples medicamentos de los pacientes con lepra / Reliability and agreement of two smear reading scales for classification and monitoring of multidrug therapy in leprosy patients
Colorado, Claudia Lucía; Sánchez, Guillermo; Guerrero, Martha Inírida; León, Clara Inés.
  • Colorado, Claudia Lucía; Centro Dermatológico Federico Lleras Acosta. Bogotá, D.C. CO
  • Sánchez, Guillermo; Centro Dermatológico Federico Lleras Acosta. Bogotá, D.C. CO
  • Guerrero, Martha Inírida; Centro Dermatológico Federico Lleras Acosta. Bogotá, D.C. CO
  • León, Clara Inés; Centro Dermatológico Federico Lleras Acosta. Bogotá, D.C. CO
Biomédica (Bogotá) ; 31(3): 403-409, sept. 2011. tab, graf
Article in Spanish | LILACS | ID: lil-617486
RESUMEN
Introducción. El diagnóstico de la lepra es clínico pero requiere métodos de clasificación para establecer el tratamiento y el pronóstico de los pacientes, acordes con su carga bacilar; ésta se detecta en extendidos de piel y se establece mediante la escala logarítmica de Ridley. En Colombia se emplea una escala semicuantitativa.Objetivo. Establecer la reproducibilidad entre observadores para las dos escalas y establecer el nivel de correlación de la concordancia entre el índice bacilar obtenido con la escala colombiana y con la de Ridley, para evaluar cuánto se pueden intercambiar. Materiales y métodos. Se estandarizó la lectura de las baciloscopias por dos lectores, con posterior evaluación del acuerdo entre observadores en un ensayo ciego. Cada lector cuantificó la carga bacilar de las muestras, usando la escala colombiana y la internacional. El grado de concordancia entre observadores se evaluó con el coeficiente kappa ponderado. El nivel de correlación de la concordancia entre las mediciones del índice bacilar, se estableció con el coeficiente de Lin. Resultados. El coeficiente kappa ponderado entre observadores fue de 0,83, y de 0,85 para las escalas colombiana y la de Ridley, respectivamente. El coeficiente de Lin fue de 0,96 para la evaluación de correlación de la concordancia de los índices bacilares obtenidos con ambas escalas. Conclusiones. La concordancia entre observadores obtenida para ambas escalas fue excelente, al igual que la correlación de la concordancia de los índices bacilares calculados con los dos métodos. Con los puntos de corte establecidos, se obtuvo un nivel de concordancia excelente, lo que garantiza que las escalas son intercambiables a la hora de establecer si la carga bacilar es alta o baja.
ABSTRACT
Introduction. After the clinical diagnosis of leprosy, classification methods are necessary to define a treatment and prognosis of patients consistent with bacterial load. Bacteria are detected in skin smear, and bacterial load typically is established by the internationally used Ridley’s logarithmic scale, However, in Colombia an alternative semiquantitative scale is used. Objective. The interobserver reproducibility was established for the Ridley and Colombia scales, and the level of correlation-matching was identified between the bacillary indices obtained in order to assess the degree of interchangeability.Materials and methods. Standardization was attained by a reading of the smears by 2 readers with subsequent, blinded evaluation of inter-observer agreement. Each reader quantified the bacterial load of for each sample (n=325) using the Colombian and the Ridley scales. The degree of interobserver agreement was assessed with weighted kappa coefficient. The level of correlation and agreement between the measurements of the bacillary index was established with coefficient of Lin. Results. The interobserver weighted kappa coefficient was 0.83 for the Colombia scale and 0.85 for the Ridley scale. The Lin coefficient was 0.96 for the correlation-matching of bacillary indexes.Conclusions. Interobserver agreement obtained for both scales was excellent as the correlation-matching bacillary indices determined with both methods. With the cut-off points yielded a good level of agreement, ensuring interchangeability between the scales defining the high or low bacterial load.
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Therapeutics / Bacillus / Weights and Measures / Leprosy Limits: Humans Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2011 Type: Article Affiliation country: Colombia Institution/Affiliation country: Centro Dermatológico Federico Lleras Acosta/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Therapeutics / Bacillus / Weights and Measures / Leprosy Limits: Humans Language: Spanish Journal: Biomédica (Bogotá) Journal subject: Medicine Year: 2011 Type: Article Affiliation country: Colombia Institution/Affiliation country: Centro Dermatológico Federico Lleras Acosta/CO