Your browser doesn't support javascript.
loading
Tabagismo e efeito de dexmedetomidina e fentanil na intubação traqueal / Cigarette smoking and the effect of dexmedetomidine and fentanyl on tracheal intubation / Tabaquismo y efecto de la dexmedetomidina y del fentanil en la intubación traqueal
Gulsoy, Kemal; Deren, Serpil; Baskan, Semih; Ornek, Dilsen; Dikmen, Bayazit.
  • Gulsoy, Kemal; Ankara Numune Training and Research Hospital. Departamento de Anaestesia e Reanimação. TR
  • Deren, Serpil; Ankara Numune Training and Research Hospital. Departamento de Anaestesia e Reanimação. TR
  • Baskan, Semih; Ankara Numune Training and Research Hospital. Departamento de Anaestesia e Reanimação. TR
  • Ornek, Dilsen; Ankara Numune Training and Research Hospital. Departamento de Anaestesia e Reanimação. TR
  • Dikmen, Bayazit; Ankara Numune Training and Research Hospital. Departamento de Anaestesia e Reanimação. TR
Rev. bras. anestesiol ; 62(2): 147-153, mar.-abr. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-618201
RESUMO
JUSTIFICATIVA E

OBJETIVOS:

Comparar os efeitos de dexmedetomidina e fentanil sobre as alterações hemodinâmicas em fumantes crônicos do sexo masculino.

MÉTODOS:

Este é um estudo prospectivo, randômico e cego. Sessenta pacientes do sexo masculino, tabagistas crônicos, com idades entre 16 e 60 anos foram selecionados. Os pacientes foram alocados aleatoriamente em dois grupos Grupo D (n = 30) recebeu 1 µg.kg-1 de dexmedetomidina e Grupo F (n = 30) recebeu 3 µg.kg-1 de fentanil em 150 mL de solução salina normal, com início 10 minutos antes da indução da anestesia. Antes da intubação, a frequência cardíaca e a pressão arterial dos pacientes foram medidas. Após a indução da anestesia para intubação endotraqueal, a frequência cardíaca e os valores da pressão arterial foram novamente medidos 1, 3 e 5 minutos após a intubação.

RESULTADOS:

A frequência cardíaca estava baixa no Grupo D antes da indução da anestesia, intubação e no primeiro e terceiro minutos pósintubação. A pressão arterial sistólica estava baixa no Grupo F antes da intubação. Embora a pressão arterial diastólica estivesse menor antes da indução da anestesia e aos 5 minutos após a intubação em ambos os grupos, ela já estava baixa no Grupo F antes mesmo da intubação. Enquanto a pressão arterial média estava baixa no Grupo D antes da indução anestésica, ela estava baixa no Grupo F antes da intubação. Os valores para o duplo produto (frequência cardíaca vezes pressão arterial sistólica) estavam baixos no Grupo D antes da indução e no 1º e 3º minutos após a intubação.

CONCLUSÕES:

A dexmedetomidina, aplicada em fumantes crônicos do sexo masculino via infusão a uma dose de 1 µg.kg-1 10 minutos antes de indução anestésica, controla melhor as elevações da frequência cardíaca e do duplo produto a 1 e 3 minutos após a intubação, comparado ao grupo que recebeu 3 µg.kg-1 de fentanil.
ABSTRACT
BACKGROUND AND

OBJECTIVES:

To compare the effect of dexmedetomidine and fentanyl on hemodynamic changes in chronic male smokers.

METHODS:

This is a prospective, randomized, blinded study. Were selected 60 chronic male smokers (aged 16 to 60 years). The patients were randomly divided into two groups Group D (n = 30) received 1 µg.kg-1 dexmedetomidine and Group F (n = 30) received 3 µg.kg-1 fentanyl in 150 mL of normal saline, beginning 10 minutes before anesthesia induction. Before intubation, the heart rate and blood pressure of patients were measured. After anesthesia induction for endotracheal intubation, heart rate and blood pressure values were measured at 1, 3, and 5 minutes after intubation.

RESULTS:

Heart rate was low in Group D before anesthesia induction, intubation, and at the 1st and 3rd minutes after intubation. Systolic arterial pressure was low in Group F before intubation. Although diastolic arterial pressure was lower before anesthesia induction and at 5 minutes after intubation in both groups, it was already low in Group F before intubation. Whereas the mean arterial pressure was low in Group D before anesthesia induction, it was low in Group F before intubation. The values for rate-pressure product were low in Group D before induction and at 1 and 3 minutes after intubation.

CONCLUSIONS:

Dexmedetomidine, which was applied via infusion at a loading dose of 1 µg.kg-1 10 minutes before anesthesia induction in chronic male smokers, better suppressed increases in heart rate and rate-pressure product at 1 and 3 minutes after intubation compared to the group receiving 3 µg.kg-1 fentanyl.
RESUMEN
JUSTIFICATIVA Y

OBJETIVOS:

Comparar los efectos de la dexmedetomidina y del fentanil sobre las alteraciones hemodinámicas en fumadores crónicos del sexo masculino.

MÉTODOS:

Este es un estudio prospectivo, randómico y ciego. Sesenta pacientes del sexo masculino, fumadores crónicos, con edades entre los 16 y los 60 años, fueron seleccionados. Los pacientes fueron divididos aleatoriamente en dos grupos Grupo D (n = 30) recibió 1 µg.kg-1 de dexmedetomidina o 3 µg.kg-1 de fentanil, y el Grupo F (n = 30) que recibió 150 mL de solución salina normal, con inicio 10 minutos antes de la inducción de la anestesia. Antes de la intubación, se mensuraron la frecuencia cardíaca y la presión arterial de los pacientes. Después de la inducción de la anestesia para la intubación endotraqueal, la frecuencia cardíaca y los valores de la presión arterial fueron medidos uno, tres y cinco minutos después de la intubación.

RESULTADOS:

La frecuencia cardíaca estaba baja en el Grupo D antes de la inducción de la anestesia, de la intubación y en el primero y tercer minutos posintubación. La presión arterial sistólica estaba baja en el Grupo F antes de la intubación. Aunque la presión arterial diastólica fuese menor antes de la inducción de la anestesia y a los cinco minutos después de la intubación en ambos grupos, ella ya estaba baja en el Grupo F antes incluso de la intubación. Mientras la presión arterial promedio estaba baja en el Grupo D antes de la inducción anestésica, estaba baja también en el Grupo F antes de la intubación. Los valores para el doble producto (frecuencia cardíaca por la presión arterial sistólica), eran bajos en el Grupo D antes de la inducción y en el 1º y 3º minutos después de la intubación.

CONCLUSIONES:

Descubrimos pues, que la dexmedetomidina, que fue aplicada en fumadores crónicos del sexo masculino vía infusión a una dosis de 1 µg.kg-1 10 minutos antes de la inducción anestésica, controla mejor las elevaciones de la frecuencia cardíaca y del doble producto a uno y tres minutos después de la intubación, comparado al grupo que recibió 3 µg.kg-1 de fentanil.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Blood Pressure / Smoking / Fentanyl / Anesthetics, Intravenous / Dexmedetomidine / Heart Rate / Hypnotics and Sedatives / Intubation, Intratracheal Type of study: Controlled clinical trial / Observational study Limits: Adolescent / Adult / Humans / Male Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2012 Type: Article Affiliation country: Turkey Institution/Affiliation country: Ankara Numune Training and Research Hospital/TR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Blood Pressure / Smoking / Fentanyl / Anesthetics, Intravenous / Dexmedetomidine / Heart Rate / Hypnotics and Sedatives / Intubation, Intratracheal Type of study: Controlled clinical trial / Observational study Limits: Adolescent / Adult / Humans / Male Language: Portuguese Journal: Rev. bras. anestesiol Journal subject: Anesthesiology Year: 2012 Type: Article Affiliation country: Turkey Institution/Affiliation country: Ankara Numune Training and Research Hospital/TR