Your browser doesn't support javascript.
loading
El cálculo del volumen plasmático mediante las curvas de aclaramiento de la transferrina marcada con 59Fe / The calculation of plasma volume by the clearance curves of the trasnferrin marked with Fe
Fundora Sarraff, Teresa A; Figueredo Ruiz, Mario; Fernández Delgado, Norma; du Défaix Gómez, Hortensia Gautier; Forrellat Barrios, Mariela; Cavill, Ivor.
  • Fundora Sarraff, Teresa A; Instituto de Hematología e Inmunología. Ciudad de La Habana. CU
  • Figueredo Ruiz, Mario; University Hospital of Wales, Cardiff. Department of Haematology.
  • Fernández Delgado, Norma; s.af
  • du Défaix Gómez, Hortensia Gautier; s.af
  • Forrellat Barrios, Mariela; s.af
  • Cavill, Ivor; s.af
Rev. cuba. hematol. inmunol. hemoter ; 17(1): 35-40, ene.-abr. 2001.
Article in Spanish | LILACS | ID: lil-628468
RESUMEN
Se calculó el volumen plasmático con transferrina marcada con 59Fe (Tf-59Fe) en 2 grupos de pacientes, uno con policitemia vera (PV) y otro con policitemia relativa (PR), mediante 2 procedimientos con el valor de la actividad a tiempo cero obtenida por regresión y con los recuentos por minuto de una muestra extraída a los 3 minutos posteriores a la inyección de la Tf-59Fe. En todos los casos la actividad a tiempo cero fue mayor que la actividad de la muestra a los 3 min. Los valores del volumen plasmático calculados por el primer procedimiento fueron menores. Las diferencias en el grupo con PV fueron significativamente mayores que las encontradas en el grupo con PR. Este estudio refuerza la utilidad de calcular la distribución de la Tf-59Fe a tiempo cero, cuando esta se ha mezclado homogéneamente en la circulación y los cambios de la curva de aclaramiento son menos críticos.
ABSTRACT
The plasma volume was calculated with transferrin marked with 59Fe (Tf-59FE) in 2 groups of patients, one with polycythemia vera and the other with relative polycythemia (RP), by using 2

methods:

with the value of the activity at zero time obtained by regresssion and with the recounts per minute of a sample taken 3 minutes after the injection of Tf-59Fe. In all the cases, the activity at zero time was higher than the activity of the sample 3 minutes later. The values of plasma volume calculated by the first method were lower. The differences in the group with PV were significantly higher than the ones found in the group with RP. This study confirms the usefulness of calculating the distribution of Tf-59Fe at zero time when this has been homogeneously mixed in the circulation and the changes in the clearance curve are less critical.

Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2001 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto de Hematología e Inmunología/CU