Your browser doesn't support javascript.
loading
Tratamientos menos invasivos: utilización de los sistemas de aire abrasivo y puntas cvd
de Carvalho, Fabíola Galbiatti; Botelho Josgrilberg, Erika; Loiola Cordeiro, Rita de Cássia; Orbegoso Flores, Victor.
  • de Carvalho, Fabíola Galbiatti; Facultad de Odontologia de Araraquara - UNESP.
  • Botelho Josgrilberg, Erika; Facultad de Odontologia de Araraquara - UNESP.
  • Loiola Cordeiro, Rita de Cássia; Facultad de Odontologia de Araraquara - UNESP.
  • Orbegoso Flores, Victor; Facultad de Odontologia de Araraquara - UNESP.
Acta odontol. venez ; 44(1): 14-17, ene. 2006. ilus
Article in Spanish | LILACS | ID: lil-629953
RESUMEN
Los sistemas de preparación cavitaria a base de aire abrasivo y puntas CVD fueron desarrollados para confeccionar cavidades con características diferentes a las obtenidas por los sistemas convencionales. Trabajos anteriores demuestran la efectividad de corte de ambos sistemas favoreciendo de esa manera la preparación de cavidades de forma más conservadora lo que permite la práctica de una “Odontología mínimamente invasiva”. El presente trabajo tiene por objetivo presentar por medio del relato de un caso clínico la forma de utilización, características de las preparaciones así como las ventajas y desventajas que ambos sistemas presentan. Los dos sistemas fueron utilizados para la remoción de lesiones de caries inicial en las superficies oclusales de los primeros molares permanentes de un paciente de 9 años de edad. En los molares 16 y 46 fue utilizado el Sistema de Aire Abrasivo y en los molares 26 y 36 el sistema de puntas CVDentusâ. De las observaciones realizadas podemos concluir que estos sistemas fueron confortables para el paciente debido a las características de funcionamiento y eficiencia de los aparatos, contribuyendo de esta forma para la colaboración y buen comportamiento del paciente, así como, facilitar la acción del operador.
ABSTRACT
The cavity systems preparation with abrasive air and burs CVD were developed to make cavities with characteristics different from the obtained by the conventional systems. Previous works demonstrate to the effectiveness of cut of both systems favoring of that way the preparation of cavities of more preservative form what the practice of a "minimally invasive Dentistry" allows. The present work must by objective present by means of the story of a clinical case the use form, characteristics of the preparations as well as the advantages and disadvantages that both systems display. Both systems were used for the removal of damages of initial decay in permanent the oclusal surfaces of first molars of a patient of 9 years of age. In molars 16 and 46 the System of Abrasive Air was used and in molars 26 and 36 the system of CVDentus. of the made observations we can conclude that these systems were comfortable for the patient due to the characteristics of operation and efficiency of the appliances, contributing of this form for the collaboration and good behavior of the patient, as well as, to facilitate the action of the operator.
RESUMO
A preparação dos sistemas da cavidade com CVD abrasivo do ar e das queimaduras foi desenvolvida a faça cavidades com as características diferentes do obtido pelos sistemas convencionais. Precedente os trabalhos demonstram à eficácia do corte de favorecer de ambos os sistemas daquele maneira a preparação das cavidades do formulário mais preservativo que a prática "um Odontologia minimamente invasiva" reserva. o trabalho atual deve pelo objetivo atual por meio da história de um caso clínico o formulário do uso, características das preparações as vantagens e desvantagens que ambos os sistemas indicam. Ambos os sistemas foram usados para a remoção dos ferimentos da deterioração inicial no permanente superfícies dos oclusales de primeiros molares de um paciente de 9 anos de idade. Nos molares 16 e 46 o sistema do ar abrasivo foram usados e nos molares 26 e 36 o sistema de CVDentus. Das observações feitas nós podemos concluir que estes sistemas eram confortáveis para paciente devido às características da operação e da eficiência dos instrumentos, contribuir deste formulário para a colaboração e comportamento bom do paciente, para facilitar a ação do operador.

Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Acta odontol. venez Journal subject: Medicina Bucal / Dentistry / Sa£de Bucal Year: 2006 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Acta odontol. venez Journal subject: Medicina Bucal / Dentistry / Sa£de Bucal Year: 2006 Type: Article