Your browser doesn't support javascript.
loading
Dermatitis de contacto por prótesis ortopédicas / Contact dermatitis for orthopaedic prostheses
Danielo, C. A; Reyna, M; Consigli (h), C.
  • Danielo, C. A; Hospital Córdoba. Servicio de Dermatología. Departamento de Dermatitis de Contacto y Dermatosis Ocupacionales. Córdoba. AR
  • Reyna, M; Hospital Córdoba. Servicio de Dermatología. Departamento de Dermatitis de Contacto y Dermatosis Ocupacionales. Córdoba. AR
  • Consigli (h), C; Hospital Córdoba. Servicio de Dermatología. Departamento de Dermatitis de Contacto y Dermatosis Ocupacionales. Córdoba. AR
Rev. argent. dermatol ; 88(3): 176-181, jul.-sep. 2007. ilus, tab
Article in Spanish | LILACS | ID: lil-634341
RESUMEN
Diversas aleaciones son utilizadas en la fabricación de prótesis ortopédicas (ej titanio, vitalio, etc), dentro de las cuales la más utilizada es la de acero inoxidable. El níquel, parte importante de esta aleación, es capaz de liberarse y provocar sensibilización, desencadenando reacciones cutáneas locales y sistémicas. De los materiales que componen la aleación para formar acero inoxidable, el níquel es el que más frecuentemente se ve implicado en reacciones cutáneas por sensibilidad, en tanto que otros como el cromo y cobalto, la posibilidad de pérdida de material a partir de la prótesis es discutida. Presentamos el caso de una paciente con dermatitis alérgica al níquel con lesiones generalizadas, que aparecieron luego del implante de prótesis ortopédicas de acero inoxidable, dando positivo para níquel sulfato en las pruebas epicutáneas.
ABSTRACT
Several alloys are used in the manufacture of orthopaedics prostheses (ie titanium, vitalium). Stainless steel is the most frequently used among them. Nickel is an important component of this alloy and may release and provoke sensitivity. Arising local and systemic cutaneous reactions. Nickel is the material composing stainless steel that ordinary is implicated in cutaneous reactions of sensitivity; the role of chrome or cobalt is still uncertain. Our patient is a woman affected of nickel contact dermatitis, with generalized reactions that appear after an implant of a stainless steel orthopaedic prosthesis. Epicutaneous tests were performed, confirming a strong sensitivity to nickel sulphate.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Dermatitis, Allergic Contact Limits: Adult / Female / Humans Language: Spanish Journal: Rev. argent. dermatol Journal subject: Dermatology Year: 2007 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Córdoba/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Prostheses and Implants / Dermatitis, Allergic Contact Limits: Adult / Female / Humans Language: Spanish Journal: Rev. argent. dermatol Journal subject: Dermatology Year: 2007 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Córdoba/AR