Impacto dos stents e do sirolimus por via oral na vasomotilidade coronariana dependente e independente do endotelio / Impact of stenting and oral sirolimus on endothelium-dependent and independent coronary vasomotion
Fernandes, Rósley Weber Alvarenga; Dantas, João Miguel; Oliveira, Dinaldo Cavalcanti; Bezerra, Hiram Grando; Brito Jr., Fabio Sandoli; Lima, Valter C..
  • Fernandes, Rósley Weber Alvarenga; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
  • Dantas, João Miguel; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
  • Oliveira, Dinaldo Cavalcanti; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
  • Bezerra, Hiram Grando; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
  • Brito Jr., Fabio Sandoli; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
  • Lima, Valter C.; Universidade Federal de São Paulo. Hospital do Rim e Hipertensão. São Paulo. BR
Arq. bras. cardiol ; 98(4): 290-299, abr. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-639415
RESUMO
FUNDAMENTO Não há consenso sobre o impacto do implante de stent sobre a função endotelial no longo prazo. Há relatos de disfunção endotelial aumentada com stent com sirolimus quando comparado com o stent metálico convencional (BMS).

OBJETIVO:

Este estudo visa a avaliar o impacto do BMS e o efeito do sirolimus por via oral sobre a função endotelial.

MÉTODOS:

Quarenta e cinco pacientes foram randomizados em três grupos BMS + altas doses de sirolimus oral (dose inicial de 15 mg, seguida de 6 mg/dia durante quatro semanas); BMS + baixa dose de sirolimus (6 mg, seguida de 2 mg por dia durante quatro semanas) e BMS sem sirolimus. Mudanças na vasoconstrição ou vasodilatação, em um segmento de 15 milímetros começando pelo extremo distal do stent em resposta a acetilcolina e nitroglicerina, foram avaliadas por angiografia quantitativa.

RESULTADOS:

Os grupos apresentaram características angiográficas semelhantes. A variação percentual de diâmetro em resposta a acetilcolina foi semelhante em todos os grupos, nos dois momentos (p = 0,469). Quatro horas após o implante de stent, o segmento alvo apresentou uma disfunção endotelial que se manteve após oito meses em todos os grupos. Em todos os grupos, a vasomotricidade independente de endotélio em resposta a nitroglicerina foi semelhante, às quatro horas e aos oito meses, com diâmetro do segmento alvo aumentado após a infusão de nitroglicerina (p = 0,001).

CONCLUSÃO:

A disfunção endotelial esteve igualmente presente no segmento distal de 15 milímetros do segmento tratado, às 4 horas e aos 8 meses após implante do stent. O sirolimus administrado por via oral durante quatro semanas para evitar a reestenose não afetou o estado de vasomotricidade endotélio dependente e independente.
ABSTRACT

BACKGROUND:

There is no consensus regarding the impact of stenting on long-term endothelial function. There have been reports of increased endothelial dysfunction with sirolimus-eluting stents as compared to bare metal stenting (BMS).

OBJECTIVE:

This study aims to assess the impact of BMS and the effect of oral sirolimus on endothelial function.

METHODS:

Forty-five patients were randomized into three groups BMS + high-dose oral sirolimus (initial dose of 15 mg, followed by 6 mg/day for four weeks); BMS + low-dose sirolimus (6 mg followed by 2 mg daily for four weeks); and BMS without sirolimus. Changes in vasoconstriction or vasodilation in a 15 mm segment starting at the distal stent end in response to acetylcholine and nitroglycerin were assessed by quantitative angiography.

RESULTS:

The groups had similar angiographic characteristics. The percent variation in diameter in response to acetylcholine was similar in all groups at the two time points (p = 0.469). Four hours after stenting, the target segment presented an endothelial dysfunction that was maintained after eight months in all groups. In all groups, endothelium-independent vasomotion in response to nitroglycerin was similar at four hours and eight months, with increased target segment diameter after nitroglycerin infusion (p = 0.001).

CONCLUSION:

The endothelial dysfunction was similarly present at the 15 mm segment distal to the treated segment, at 4 hours and 8 months after stenting. Sirolimus administered orally during 4 weeks to prevent restenosis did not affect the status of endothelium-dependent and independent vasomotion.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Vasomotor System / Endothelium, Vascular / Stents / Coronary Vessels / Sirolimus / Immunosuppressive Agents Type of study: Controlled clinical trial Limits: Adult / Female / Humans Language: Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Vasomotor System / Endothelium, Vascular / Stents / Coronary Vessels / Sirolimus / Immunosuppressive Agents Type of study: Controlled clinical trial Limits: Adult / Female / Humans Language: Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de São Paulo/BR