Your browser doesn't support javascript.
loading
Análise da confiabilidade e reprodutibilidade da goniometria em relação à fotogrametria na mão / Analysis of the reliability and reproducibility goniometry photogrammetry regarding the hand
Carvalho, Rosana Martins Ferreira de; Mazzer, Nilton; Barbieri, Claudio Henrique.
  • Carvalho, Rosana Martins Ferreira de; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
  • Mazzer, Nilton; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
  • Barbieri, Claudio Henrique; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Ribeirão Preto. BR
Acta ortop. bras ; 20(3): 139-149, 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-640105
RESUMO

OBJETIVO:

Avaliar a confiabilidade intra e interexaminadores e a reprodutibilidade da goniometria em relação à fotogrametria na mão, comparando os ângulos da abdução de polegar, flexão da AIFP do II dedo e flexão da AMCF do V dedo.

MÉTODOS:

PARTIciparam deste estudo 30voluntários foram divididos em 3 grupos, um grupo de 10 estudantes de Fisioterapia, outro por 10 fisioterapeutas e o terceiro com 10 terapeutas da mão. Cada avaliador realizou as medidas no mesmo molde de mão, utilizando o goniômetro e em seguidadois softwares de fotogrametria, o CorelDraw® e o ALCimagem®.

RESULTADOS:

Os resultados revelaram que os grupos e os métodos propostos apresentam confiabilidade interexaminadores no geral classificada como excelente (ICC 0,998 I.C. 95% 0,995 - 0,999). Na avaliação intraexaminadores, foi encontrado excelente nível de confiabilidade entre os três grupos. Na comparação entre os grupos para cada ângulo e cada método, observou-se que não houve diferença significativa entre os grupos para a maioria das medidas.

CONCLUSÃO:

A goniometria e a fotogrametria são métodos confiáveis e reprodutíveis para avaliação de medidas na mão. Porém, pela escassez de referências semelhantes, necessita-se de estudos aprofundados para definição de parâmetros de normalidade entre os métodos nas articulações da mão. Nível de Evidência II, Estudo Diagnóstico.
ABSTRACT

OBJECTIVE:

To evaluate the intra and inter and reproducibility of goniometry compared to photogrammetryin hand, comparing the angles of abduction of thumb flexion, flexion of proximal interphalangeal joint of the index finger and flexion of the metacarpophalangeal joint of the fifth finger.

METHODS:

The study included 30 volunteers were divided in to three groups, one group of 10 students of physiotherapy for 10 physiotherapist sand other third with 10 therapist shand. Each examiner performed the measure mentsin the same mold by hand, using the goniometer and then two photogrammetry software, Corel Draw® and ALCimagem®.

RESULTS:

The results revealed that the groups and the methods proposed inter examiner reliability have generally rated as excellent (ICC 0.99895% CI0.995 to 0.999) In assessing rater was found excellent level of reliability among the three groups. Incomparison between groups for each angle and each method, we found that there was no significant difference between groups for most measures.

CONCLUSION:

Goniometry and photogramme tryare reliable and reproducible methods to evaluate measures in hand. However, the scarcity of similar references, it requires detailed studies to define normal parameters of the methods in the joints of the hand. Level of Evidence II, Diagnostic Study.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Photogrammetry / Reproducibility of Results / Range of Motion, Articular / Hand Joints / Arthrometry, Articular Limits: Female / Humans / Male Language: Portuguese Journal: Acta ortop. bras Journal subject: Orthopedics Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Photogrammetry / Reproducibility of Results / Range of Motion, Articular / Hand Joints / Arthrometry, Articular Limits: Female / Humans / Male Language: Portuguese Journal: Acta ortop. bras Journal subject: Orthopedics Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de São Paulo/BR