Your browser doesn't support javascript.
loading
Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho / Comparative study between gelatinous and hard spheres of silicone in rabbit eviscerated scleral cavity
Kanamura, Mayumi Shirota; Padovani, Carlos Roberto; Pereira, Elenize Jamas; Mamprim, Maria Jaqueline; Schellini, Silvana Artioli.
  • Kanamura, Mayumi Shirota; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Padovani, Carlos Roberto; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Pereira, Elenize Jamas; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Mamprim, Maria Jaqueline; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
  • Schellini, Silvana Artioli; Universidade Estadual Paulista Júlio de Mesquita Filho. Botucatu. BR
Arq. bras. oftalmol ; 75(3): 197-201, maio-jun. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-644447
RESUMO

OBJETIVO:

Avaliar e comparar a biocompatibilidade de esferas de silicone gelatinosas e rígidas em cavidades evisceradas de coelhos.

MÉTODOS:

Trinta coelhos tiveram o olho direito eviscerado com implantação de esferas de silicone gelatinosas (Grupo I) ou rígidas (Grupo II). Foi realizada avaliação clínica diária, ultrassonografia da cavidade orbitária, análise histológica e morfométrica da pseudocápsula que se formou ao redor dos implantes aos 7, 30 e 90 dias após a cirurgia, com avaliação estatística dos resultados.

RESULTADOS:

Houve boa integração das esferas com os tecidos orbitários e semelhança de resposta tecidual com ambas as esferas. Duas esferas de silicone gelatinosas e uma rígida extruíram. A pseudocápsula que se formou ao redor das esferas gelatinosas foi mais organizada, com espessura e reação inflamatória menores que a observada nas esferas rígidas.

CONCLUSÕES:

Esferas de silicone gelatinosas e rígidas tiveram boa integração tecidual em cavidades evisceradas de coelhos.
ABSTRACT

PURPOSE:

To evaluate and to compare the biocompatibility of gelatinous and hard silicone spheres placed into eviscerated scleral cavities of rabbits.

METHOD:

Thirty rabbits underwent right eye evisceration surgery and replacement of orbital volume using gelatinous (Group I) or hard silicone (Group II) spheres. Seven, 30 and 90 days after the surgical procedure, clinical assessment, ultrasound of the orbit, histological and morphometric evaluation of the pseudocapsule were performed. Data was submitted to statistical analysis.

RESULTS:

Similarity of tissue response was observed with both materials. Two gelatinous and one hard silicone spheres had extrusion. The pseudocapsule around the gelatinous spheres was better organized, thinner and with less inflammatory reaction.

CONCLUSIONS:

Both spheres had good integration to the orbital tissue in rabbit eviscerated cavities.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Sclera / Silicones / Biocompatible Materials / Eye Evisceration / Orbital Implants Type of study: Prognostic study Limits: Animals Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista Júlio de Mesquita Filho/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Sclera / Silicones / Biocompatible Materials / Eye Evisceration / Orbital Implants Type of study: Prognostic study Limits: Animals Language: Portuguese Journal: Arq. bras. oftalmol Journal subject: Ophthalmology Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Estadual Paulista Júlio de Mesquita Filho/BR