Your browser doesn't support javascript.
loading
Do nistagmo às provas calóricas com ar e com água / From nystagmus to the air and water caloric tests
Barros, Anna Carolina Marques Perrella de; Caovilla, Heloisa Helena.
  • Barros, Anna Carolina Marques Perrella de; Universidade Federal de São Paulo. Escola Paulista de Medicina. Programa de Pós-Graduação em Distúrbios da Comunicação Humana.
  • Caovilla, Heloisa Helena; Universidade Federal de São Paulo. Escola Paulista de Medicina.
Braz. j. otorhinolaryngol. (Impr.) ; 78(4): 120-125, jul.-ago. 2012. tab
Article in Portuguese | LILACS | ID: lil-646782
RESUMO
A prova calórica é uma importante ferramenta na avaliação da função labiríntica.

OBJETIVO:

Comparar o nistagmo pós-calórico da prova com ar a 50ºC e 24ºC com o da prova com água a 44ºC e 30ºC. Desenho científico Estudo clínico cruzado randomizado. MATERIAL E

MÉTODO:

40 indivíduos hígidos submetidos à avaliação da função vestibular incluindo a prova calórica com ar a 50ºC e 24ºC e com água a 44ºC e 30ºC.

RESULTADOS:

À comparação das provas com ar e com água, não houve diferença significante entre os valores da velocidade angular da componente lenta (VACL) do nistagmo pós-calórico quanto à ordem de realização das estimulações, entre as orelhas e entre os valores de predomínio labiríntico e de preponderância direcional. Os valores da VACL foram maiores nas estimulações com água (p = 0,008; p < 0,001) e a temperatura fria evocou respostas mais intensas (p < 0,001).

CONCLUSÃO:

À comparação entre as provas com ar a 50ºC e 24ºC e com água a 44ºC e 30ºC, observam-se valores de velocidade da componente lenta similares em ambas as orelhas, maiores na temperatura fria e na prova com água e resultados semelhantes de predomínio labiríntico ou de preponderância direcional do nistagmo pós-calórico em ambas as provas.
ABSTRACT
The caloric test is an important tool for the assessment of labyrinthine function.

OBJECTIVE:

To compare the nystagmus response in the caloric tests with air at 50ºC and 24ºC and with water at 44ºC and 30ºC. Study

Design:

Randomized crossover clinical trial. MATERIALS AND

METHODS:

40 healthy individuals were submitted to a neurotological evaluation, including caloric tests with air at 50ºC and 24ºC and water at 44ºC and 30ºC.

RESULTS:

Comparing the air and water caloric tests, there were no significant differences among the post-caloric nystagmus slow-phase velocity in relation to the stimulation order, between ears and between the values of unilateral weakness and directional preponderance. The slow-phase velocity values were higher with water (p = 0.008, p < 0.001), and cold stimulation produced stronger responses (p < 0.001).

CONCLUSION:

Comparing 50ºC and 24ºC air caloric test and 44ºC and 30ºC water caloric test, we observed similar slow-phase velocity values for both ears, higher responses in the cold temperature and in the test with water, and similar results of unilateral weakness or directional preponderance for post-caloric nystagmus in both tests.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Nystagmus, Physiologic / Caloric Tests Type of study: Controlled clinical trial Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Braz. j. otorhinolaryngol. (Impr.) Journal subject: Otolaryngology Year: 2012 Type: Article Affiliation country: Brazil

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Nystagmus, Physiologic / Caloric Tests Type of study: Controlled clinical trial Limits: Adolescent / Adult / Female / Humans / Male Language: Portuguese Journal: Braz. j. otorhinolaryngol. (Impr.) Journal subject: Otolaryngology Year: 2012 Type: Article Affiliation country: Brazil