Your browser doesn't support javascript.
loading
Triagem neonatal para hiperplasia adrenal congênita / Neonatal screening for congenital adrenal hyperplasia
Barra, Cristina Botelho; Silva, Ivani Novato; Pezzuti, Isabela Leite; Januário, José Nélio.
  • Barra, Cristina Botelho; Universidade Federal do Minas Gerais. Faculdade de Medicina. Belo Horizonte. BR
  • Silva, Ivani Novato; Universidade Federal de Minas Gerais. FM Hospital das Clínicas. Departamento de Pediatria Divisão de Endocrinologia Pediátrica. Belo Horizonte. BR
  • Pezzuti, Isabela Leite; Universidade Federal do Minas Gerais. Faculdade de Medicina. Belo Horizonte. BR
  • Januário, José Nélio; UFMG. FM. Curso de Doutorado Departamento de Clínica Médica Núcleo de Ações e Pesquisa em Apoio Diagnóstico. Belo Horizonte. BR
Rev. Assoc. Med. Bras. (1992) ; 58(4): 459-464, July-Aug. 2012. ilus
Article in Portuguese | LILACS | ID: lil-646888
RESUMO

OBJETIVO:

A eficácia da triagem neonatal para redução de morbimortalidade das crianças com hiperplasia adrenal congênita (HAC) é a principal justificativa para sua implantação. Um dos desafios para sua realização é a determinação do ponto de corte para a medida laboratorial da 17-hidroxiprogesterona (17OHP) que apresente adequado custo/benefício. Neste estudo foram identificados fatores intervenientes nos resultados do projeto-piloto de triagem neonatal para HAC, realizado em Minas Gerais.

MÉTODOS:

Rastreamento neonatal entre 09/2007 e 05/2008, com dosagens da 17OHP de amostras de sangue colhidas no calcanhar, no 5º dia de vida (papel-filtro), processadas pelo método UMELISA 17-OH Progesterona NEONATAL®. Os pontos de corte foram 80 e 160 nmol/L, para crianças saudáveis ou não, respectivamente.

RESULTADOS:

A incidência de HAC foi 119.939 em 159.415 crianças triadas. O percentil 99 (p99) da 17OHP, na primeira amostra, foi 108 nmol/L. Em 13.298 recém-nascidos com peso informado, os p99 da 17OHP foram, respectivamente, 344 nmol/L para <1500 g, 260 nmol/L para 1500 a 1999 g, 221 nmol/L para 2000 a 2499 g, e 109 nmol/L para > 2500 g. A taxa de reconvocação para consulta médica foi 0,31%. A sensibilidade do teste foi 100%, a especificidade, 99,6% e o valor preditivo positivo, 2,2%. Ajustando-se o ponto de corte da 17OHP para 110 nmol/L e 220 nmol/L, projetou-se redução em 76% dos encaminhamentos para consulta.

CONCLUSÃO:

Adoção dos pontos de corte para 17OHP, considerando peso de nascimento, apresentou-se como medida custo-efetiva para redução de falso-positivos. Os resultados desse estudo piloto sugerem que a triagem para HAC possa beneficiar a população infantil.
ABSTRACT

OBJECTIVE:

The effectiveness of neonatal screening for reducing morbimortality in children with congenital adrenal hyperplasia (CAH) is the main justification for its implementation. One of the challenges for its implementation is to determine the cutoff value for laboratory measurement of 17-hydroxyprogesterone (17OHP) with appropriate cost-effectiveness. This study identified factors affecting the results of the pilot project of newborn screening for CAH, performed in the state of Minas Gerais, Brazil.

METHODS:

Neonatal screening performed between September, 2007 and May, 2008, with 17OHP measurements performed in blood samples taken from the heel (filter paper), on the 5th day of life, processed by the UMELISA 17-OH Progesterona NEONATAL® method. The cutoff value was 80 and 160 nmol/L for healthy children or not, respectively.

RESULTS:

The incidence of CAH was 119,939 in 159,415 children screened. The 99th percentile (p99) of 17OHP in the first sample was 108 nmol/L. In 13,298 newborns whose weight had been reported, the p99 of 17OHP were, respectively 344 nmol/L for weight < 1,500 g; 260 nmol/L for weight between 1,500 and 1,999 g; 221 nmol/L for weight between 2,000 and 2,499 g; 109 nmol/L for weight > 2,500g. The rate of recall for medical consultation was 0.31%. The test sensitivity was 100%, specificity was 99.6%, and the positive predictive value was 2.2%. By adjusting the cutoff values of 17OHP to 110 nmol/L and 220 nmol/L, a 76% decrease in consultation referrals was projected.

CONCLUSION:

The use of 17OHP cutoff values, considering birth weight, was a cost-effective measure to reduce false positives. The results of this pilot study suggest that screening for CAH might benefit the pediatric population.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Birth Weight / Neonatal Screening / Adrenal Hyperplasia, Congenital Type of study: Diagnostic study / Evaluation studies / Incidence study / Observational study / Prognostic study / Risk factors / Screening study Limits: Female / Humans / Male / Infant, Newborn Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. Assoc. Med. Bras. (1992) Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: UFMG/BR / Universidade Federal de Minas Gerais/BR / Universidade Federal do Minas Gerais/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Birth Weight / Neonatal Screening / Adrenal Hyperplasia, Congenital Type of study: Diagnostic study / Evaluation studies / Incidence study / Observational study / Prognostic study / Risk factors / Screening study Limits: Female / Humans / Male / Infant, Newborn Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. Assoc. Med. Bras. (1992) Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: UFMG/BR / Universidade Federal de Minas Gerais/BR / Universidade Federal do Minas Gerais/BR