Your browser doesn't support javascript.
loading
RNI Point-of-care test (POCT): esperança ou ilusão? / Point-of-care test (POCT) INR: hope or illusion?
Dusse, Luci Maria Sant'Ana; Oliveira, Nataly Carvalho; Rios, Danyelle Romana Alves; Marcolino, Milena Soriano.
  • Dusse, Luci Maria Sant'Ana; Universidade Federal de Minas Gerais. Faculdade de Farmácia. Departamento de Análises Clínicas e Toxicológicas. Belo Horizonte. BR
  • Oliveira, Nataly Carvalho; Universidade Federal de Minas Gerais. Faculdade de Farmácia. Departamento de Análises Clínicas e Toxicológicas. Belo Horizonte. BR
  • Rios, Danyelle Romana Alves; Universidade Federal de Minas Gerais. Faculdade de Farmácia. Departamento de Análises Clínicas e Toxicológicas. Belo Horizonte. BR
  • Marcolino, Milena Soriano; Universidade Federal de Minas Gerais. Curso de Biomedicina. Belo Horizonte. BR
Rev. bras. cir. cardiovasc ; 27(2): 296-301, abr.-jun. 2012.
Article in Portuguese | LILACS | ID: lil-649607
RESUMO
Na última década, foram desenvolvidos os testes point-of-care visando à geração rápida de resultados de exames. Na área da hemostasia, a razão normatizada internacional, o RNI point-of-care test (RNI-POCT), constitui o principal exame dessa nova proposta. Esse teste tem grande potencial de benefício em situações em que o resultado rápido da RNI influencia a tomada de decisão clínica, como no acidente vascular cerebral isquêmico agudo, antes de procedimentos cirúrgicos e durante cirurgias cardíacas, além de permitir que o próprio paciente faça a monitoração da anticoagulação oral. Entretanto, a precisão e a acurácia da RNI-POCT ainda precisam ser aprimoradas para aumentar a eficácia e a eficiência do teste. A RDC/ANVISA Nº 302 deixa claro que os testes POCT devem ser supervisionados pelo responsável técnico do Laboratório Clínico nas fases pré-analítica, analítica e pós-analítica. Na prática, o laboratório não participa da execução desses testes e liberação dos resultados, não sendo, portanto, o mais indicado para garantir a qualidade dos mesmos. Os clínicos, especialmente aqueles envolvidos com a anticoagulação oral de pacientes, têm grande expectativa na incorporação da RNI-POCT na prática diária, apesar das limitações desse método. Esses profissionais mostram-se dispostos a treinar o paciente para realizar o teste, mas legalmente não são os responsáveis pela qualidade do mesmo e não estão preparados para a manutenção dos equipamentos. A definição do responsável pelo RNI-POCT precisa ser reavaliada pelos órgãos competentes, de forma a garantir que seja cumprida, e constitui etapa essencial para assegurar a qualidade do teste e, consequentemente, sua maior utilização.
ABSTRACT
In the last decade, point-of-care tests were developed to provide rapid generation of test results. These tests have increasingly broad applications. In the area of hemostasis, the international normalized ratio, INR point-of-care test (POCT INR), is the main test of this new proposal. This test has great potential benefit in situations where the quick INR results influences clinical decision making, as in acute ischemic stroke, before surgical procedures and during cardiac surgery. The INR POCT has the potential to be used for self-monitoring of oral anticoagulation in patients under anticoagulant therapy. However, the precision and accuracy of INR POCT still need to be enhanced to increase effectiveness and efficiency of the test. Additionally, the RDC / ANVISA Number 302 makes clear that the POCT testing must be supervised by the technical manager of the Clinical Laboratory in the pre-analytical, analytical and post-analytical. In practice, the Clinical Laboratory does not participate in the implementation of POCT testing or release of the results. Clinicians have high expectation with the incorporation of INR POCT in clinical practice, despite the limitations of this method. These professionals are willing to train the patient to perform the test, but are not legally responsible for the quality of it and are not prepared for the maintenance of equipment. The definition of who is in charge for the test must be one to ensure the quality control.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Point-of-Care Systems / International Normalized Ratio / Anticoagulants Type of study: Prognostic study Limits: Humans Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Point-of-Care Systems / International Normalized Ratio / Anticoagulants Type of study: Prognostic study Limits: Humans Country/Region as subject: South America / Brazil Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2012 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR