Your browser doesn't support javascript.
loading
Imagem e mecânica pulmonar regional em duas estratégias protetoras de ventilação mecânica (ARDSNet versus PEEP ajustada pela tomografia de impedância elétrica): um estudo de longo prazo em modelo experimental / Image and regional lung mechanics in two protective ventilatory strategies (ARDSNet versus PEEP adjusted by electrical impedance tomography): a long term experimental model study
São Paulo; s.n; 2012. 95 p.
Thesis in Portuguese | LILACS | ID: lil-655463
RESUMO

Introdução:

As estratégias ventilatórias protetoras têm contribuído para a redução da letalidade da Síndrome do Desconforto Respiratório Agudo (SDRA), mas ainda está em debate qual, entre as diversas existentes, é a mais eficaz. A estratégia ARDSNet, muito utilizada na prática clínica, prioriza a redução do volume corrente para minimizar a hiperdistensão. As estratégias Open Lung Approach (OLA), além de procurarem reduzir a hiperdistensão, buscam minimizar o colapso pulmonar para evitar a atelectasia cíclica. Os métodos para ajuste da PEEP ideal nas estratégias OLA apresentam imperfeições difícil implementação, não permitem avaliação regional do pulmão ou não podem ser realizados a beira leito. Uma estratégia OLA guiada por Tomografia de Impedância Elétrica (TIE) que permite a avaliação regional pulmonar de modo contínuo e a beira leito pode trazer benefícios.

Objetivo:

Comparar os efeitos fisiológicos (imagem, mecânica e trocas gasosas) ao longo de 42 h entre duas estratégias ventilatórias protetoras em um modelo suíno de SDRA (estratégia ARDSNET X estratégia guiada por TIE (PEEPTIE). Comparar a mecânica pulmonar e troca gasosa nas duas estratégias ao final das 42 h de ventilação, em uma mesma condição de ventilação, para avaliar efeitos duradouros das estratégias sobre o parênquima pulmonar.

Métodos:

Sete porcos foram submetidos a ventilação mecânica por 42 horas em cada uma das duas estratégias. A lesão pulmonary foi induzida com lavagem de solução fisiológica associada a ventilação lesiva. No grupo PEEPTIE, a PEEP foi ajustada pela TIE após manobra de recrutamento, mantendo o pulmão com o mínimo de colapso menor que 5 por cento), enquanto que na estratégia ARDSNet era ajustada através da tabela PEEPxFiO2. O volume corrente foi mantido entre 4-6ml/Kg em ambas estratégias, com a pressão de platô menor que 30 cmH2O.

Resultados:

Oxigenação e mecânica pulmonary eram semelhantes em ambos os grupos após a lesão pulmonar. Durante as 42h de protocolo, a troca gasosa foi...
ABSTRACT

Introduction:

Protective ventilatory strategies have contributed for the reduction in Acute Respiratory Distress Syndrome (ARDS) mortality, but so far there is still debate which strategy is more effective. The ARDSNet strategy, used widely in the clinical practice, emphasizes in tidal volume reduction to minimize hiperdistension. The Open Lung Approach (OLA), besides the reduction of hiperdistension, emphasizes reduction of lung collapse to avoid tidal recruitment. The methods to adjust ideal PEEP in the OLA strategies have some imperfections difficult implementation, do not allow regional lung evaluation or cant be performed at the bedside. The OLA strategy guided by Electrical Impedance Tomography (EIT) which allows a continuous and regional lung evaluation can bring benefits.

Objective:

Compare physiological effects (image, mechanics and gas exchange) during a period of 42 hours between two protective ventilatory strategies in an ARDS suine model (ARDSNet strategy x strategy guided by EIT PEEPTIE). Compare lung mechanics and gas exchange in both strategies at the end of 42 hours of ventilation, in the same ventilation condition, to evaluate the strategies longtime effects on lung parenchyma.

Methods:

Seven suines were submitted to mechanical ventilation for 42 hours in each ventilator strategy. Lung injury was induced by saline lavage associated to injurious mechanical ventilation. In the PEEPTIE arm, PEEP was selected by the electrical impedance tomography after a recruitment maneuver, trying to keep lung collapse at minimum, while the ARDSnet group followed a PEEPxFiO2 table. Tidal volume of 4-6ml/kg was maintained in both strategies, with a plateau pressure not higher than 30 cmH2O.

Results:

Oxygenation and lung mechanics were equally impaired in both arms after injury. During the 42 hours of protocol, gas exchange was significantly higher in the PEEPTIE arm as compared to the ARDSNet arm in the beginning (p< 0.01) and at the end of the protocol...
Subject(s)
Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Respiratory Distress Syndrome / Pulmonary Atelectasis / Electric Impedance / Acute Lung Injury Type of study: Practice guideline Limits: Animals Language: Portuguese Year: 2012 Type: Thesis

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Respiratory Distress Syndrome / Pulmonary Atelectasis / Electric Impedance / Acute Lung Injury Type of study: Practice guideline Limits: Animals Language: Portuguese Year: 2012 Type: Thesis