Objetivo:
O objetivo deste estudo foi avaliar o desajuste marginal vertical entre implante e diferentes componentes protéticos (pré-fabricados e fundidos). Material emétodo:
Foram utilizados três grupos (n = 4) grupo MP - componentes pré-fabricados preparáveis; grupo UI - UCLA calcináveis com base metálica em Co-Cr; grupo UF - UCLA com base metálica fundida em Co-Cr. Os espécimes foram analisados em microscópio eletrônico de varredura, no qual foi avaliado o desajuste marginal vertical. Os dados foram submetidos aos testes estatísticos de Kruskal-Wallis e Mann-Whitney (a = 0,05).Resultado:
As médias de desajuste (µm) encontradas foram MP = 1,52 (±2,1); UI = 6,15 (±2,5); UF = 6,04 (±2,9). O munhão personalizável apresentou menor desajuste marginal vertical quando comparado ao pilar UCLA com base metálica em Co-Cr antes e após processo de fundição.Conclusão:
Apesar das diferenças observadas, todos os componentes apresentaram níveis de adaptação aceitáveis para utilização clínica.ABSTRACT
Objective:
The aim of the study was to evaluate the vertical marginal misfit between implant and different prosthetic abutments (prefabricated and castings). Material andmethod:
The samples were divided into three groups (n = 4) group MP - personalized abutment; group UI - UCLA with metallic base in Co-Cr; group UF - UCLA with metallic base casting in Co-Cr. The specimens were analyzed in scanning electronic microscope, where it was evaluated the vertical marginal misfit. The data were submitted to the Kruskal-Wallis and Mann-Whitney statistical tests (a = 0.05).Result:
The misfit means were MP = 1.52 (±2.1); UI = 6.15 (±2.5); UF = 6.04 (±2.9). The personalized abutment showed the smallest vertical marginal misfit when compared to the UCLA abutment with metallic base in Co-Cr before and after casting process.Conclusion:
All components presented acceptable fit levels for the use clinical, despite the observed differences.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Microscopy, Electron, Scanning
/
Dental Implants
/
Dental Prosthesis
/
Prosthesis Fitting
/
Statistics, Nonparametric
/
Dental Prosthesis, Implant-Supported
Language:
Portuguese
Journal:
Rev. odontol. UNESP (Online)
Journal subject:
Dentistry
Year:
2012
Type:
Article
Affiliation country:
Brazil
Institution/Affiliation country:
Faculdade Meridional/BR
Similar
MEDLINE
...
LILACS
LIS