Your browser doesn't support javascript.
loading
Hemólise na circulação extracorpórea: correlação com tempo e procedimentos realizados / Hemolysis in extracorporeal circulation: relationship between time and procedures
Vieira Junior, Francisco Ubaldo; Antunes, Nilson; Vieira, Reinaldo Wilson; Álvares, Lúcia Madalena Paulo; Costa, Eduardo Tavares.
  • Vieira Junior, Francisco Ubaldo; Instituto Federal de São Paulo.
  • Antunes, Nilson; Instituto Federal de São Paulo.
  • Vieira, Reinaldo Wilson; Instituto Federal de São Paulo.
  • Álvares, Lúcia Madalena Paulo; Instituto Federal de São Paulo.
  • Costa, Eduardo Tavares; Instituto Federal de São Paulo.
Rev. bras. cir. cardiovasc ; 27(4): 535-541, out.-dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-668115
RESUMO

INTRODUÇÃO:

A circulação extracorpórea (CEC) é indispensável para a maioria das operações cardíacas, mas causa danos significantes ao sangue, dentre eles a hemólise.

OBJETIVO:

Quantificar as taxas de hemólise em diferentes tempos nas operações para revascularização do miocárdio com uso de CEC.

MÉTODOS:

Foram medidas as taxas de hemólise de 22 pacientes em 6 tempos distintos durante a revascularização do miocárdio com uso de CEC T0 - antes do início da CEC, T1 - 5 minutos após o início da CEC, T2 - com 30 minutos de CEC, T3 - imediatamente antes do despinçamento da aorta, T4 - imediatamente antes da passagem do volume residual para o paciente e T5 - 5 minutos após o término da passagem do volume residual para o paciente. Foram calculadas as taxas de hemólise entre os intervalos de tempo T0-T1; T1-T2; T2-T3; T3-T4 e T4-T5.

RESULTADOS:

Os primeiros 5 minutos após a CEC demonstraram maior taxa de hemólise (P = 0,0003) em comparação às outras taxas calculadas, representando 29% da hemólise total até T4 (imediatamente antes da passagem do volume residual para o paciente).

CONCLUSÃO:

Não foram observadas variações significantes nas taxas de hemólise durante a aspiração na raiz da aorta (P > 0,38) nem com o procedimento utilizado para a passagem do volume residual de sangue no circuito para os pacientes.
ABSTRACT

INTRODUCTION:

Extracorporeal circulation (EC) is very important in cardiac surgery but causes significant damage to the blood, including hemolysis.

OBJECTIVE:

To quantify the rate of hemolysis at different times during EC in elective coronary artery bypass grafting.

METHODS:

We measured rates of hemolysis of 22 patients at 6 different times during myocardial revascularization during EC T0 - before the start of EC, T1 - five minutes after of the EC initiation, T2 - 30 minutes of EC, T3 - immediately before the aortic unclamping, T4 - immediately before passage of the residual volume to the patient and T5 - five minutes after the passage of the residual volume to the patient. Rates of hemolysis were calculated between the intervals of time T0-T1; T1-T2; T2-T3; T3-T4 and T4-T5.

RESULTS:

The first 5 minutes after the EC showed the highest rate of hemolysis (P = 0.0003) compared to the others calculated rates, representing 29% of the total haemolysis until T4 (Immediately before passage of the residual volume to the patient).

CONCLUSION:

There were no significant changes in the rate of hemolysis during the suction in the aortic root (P> 0.38), nor with the procedure used for the passage of the residual volume of blood in the circuit to the patient.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Coronary Artery Bypass / Extracorporeal Circulation / Hemolysis Limits: Female / Humans / Male Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2012 Type: Article Affiliation country: Brazil

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Coronary Artery Bypass / Extracorporeal Circulation / Hemolysis Limits: Female / Humans / Male Language: Portuguese Journal: Rev. bras. cir. cardiovasc Journal subject: Cardiology / General Surgery Year: 2012 Type: Article Affiliation country: Brazil